Zurück zu den Ergebnissen
Bibliografischer Datensatz · Ansicht und Zugriff
Artículo

A reprodutibilidade da medida do volume endometrial por meio do VOCAL: a importância do passo de rotação The reproducibility of VOCAL endometrial volume measurement: importance of the step rotation

Wellington de Paula Martins et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2006

Ergänzendes Material verfügbar
Schnellübersicht. Prüfen Sie die grundlegenden Angaben und öffnen Sie den Inhalt über die Hauptschaltfläche. Die Seite zeigt nur die Informationen, die zum Identifizieren, Zitieren und Öffnen des Werks nötig sind.
Fortlaufende Publikation

A FEBRASGO e o Novo Ano

Diese fortlaufende Publikation enthält 195 zugehörige Inhalte.

Zugriff auf die Ressource

Öffnen Sie den Inhalt über die Hauptoption oder wählen Sie eine andere verfügbare Quelle.

DOAJ DOAJ Articles
Entrar por DOAJ
Hauptzugriff

Ergänzendes Material verfügbar

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Material öffnen

Übersicht

Descripción general del contenido del recurso.

OBJETIVOS: avaliar a reprodutibilidade intra-observador e interobservador da medida do volume endometrial utilizando ultra-sonografia tridimensional (3D) e o programa VOCAL® (Virtual Organ Computer-aided AnaLysis). MÉTODOS: um bloco ultra-sonográfico 3D do endométrio foi obtido de cinco pacientes inférteis voluntárias que apresentavam diferentes volumes endometriais. Para cada bloco 3D, o volume endometrial foi calculado utilizando o modo manual em quatro diferentes passos de rotação (30º, 15º, 9º e 6º) por dois diferentes observadores. Dez medidas foram obtidas para cada rotação e por cada observador. Testamos a diferença entre as médias com o one-way ANOVA e o pós-teste de Tukey e a reprodutibilidade com os coeficientes de correlação intraclasse. RESULTADOS: as medidas realizadas com passo de rotação de 30º foram associadas a médias significativamente menores em 3 das 5 pacientes. Não houve diferença entre as médias obtidas pelos passos de rotação de 15º, 9º ou 6º. Em nenhuma das avaliações foi notada diferença entre as médias obtidas pelos dois observadores. Os coeficientes de correlação intraclasse foram significativamente menores com o passo de rotação de 30º (todos abaixo de 0,984) que com os outros passos de rotação (todos acima de 0,996). CONCLUSÕES: o uso de passos de rotação de 15º ou menos apresentou medidas reprodutíveis do volume endometrial: não houve diferença significativa entre as médias obtidas pelos dois observadores, associado ao alto coeficiente de correlação intraclasse (>0,996). É recomendável o uso do passo de rotação de 15º, pois demora menos para ser obtido em comparação com 6º e 9º.<br>PURPOSE: to determine the intraobserver and interobserver reproducibility of endometrial volume measurements using the VOCAL®-imaging program (Virtual Organ Computer-aided AnaLysis). METHODS: one three-dimensional (3-D) ultrasound dataset of the endometrium was obtained from each of five infertile women with different endometrial volumes. For each 3-D dataset, the endometrial volume was calculated by two different observers using the manual mode in four different rotational steps (30º, 15º, 9º and 6º). Ten measurements were obtained with each method and observer from each 3-D dataset. We have used one-way ANOVA and the Tukey post-test to verify the differences among means and the intraclass correlation coefficient to test reliability. RESULTS: rotational methods employing a rotation step of 30º were associated with lower endometrial volume readings in 3 of the 5 patients. There were no significant differences between the means obtained by the 15º, 9º or 6º step rotation. No significant difference was found between the means obtained by the two different observers. The intraclass correlation coefficients were significantly lower with 30º (all under 0.984) than with the other step rotations (all above 0.996). CONCLUSIONS: the use of a rotational step of 15º or less provides reliable readings of endometrial volume: there were no significant differences between the means calculated by the two observers, associated with highintraclass correlation coefficient (>0.996). We recommend the 15º step rotation because it is quicker to be performed than 6º and 9º.

Zitieren

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, W. D. P. M. E. (2006). A reprodutibilidade da medida do volume endometrial por meio do VOCAL: a importância do passo de rotação The reproducibility of VOCAL endometrial volume measurement: importance of the step rotation. https://doi.org/10.1590/S0100-72032006000100007

MLA

al, Wellington de Paula Martins et. "A reprodutibilidade da medida do volume endometrial por meio do VOCAL: a importância do passo de rotação The reproducibility of VOCAL endometrial volume measurement: importance of the step rotation." 2006. https://doi.org/10.1590/S0100-72032006000100007.

Chicago

al, Wellington de Paula Martins et. 2006. "A reprodutibilidade da medida do volume endometrial por meio do VOCAL: a importância do passo de rotação The reproducibility of VOCAL endometrial volume measurement: importance of the step rotation.". https://doi.org/10.1590/S0100-72032006000100007.

Harvard

al, W. D. P. M. E. 2006, A reprodutibilidade da medida do volume endometrial por meio do VOCAL: a importância do passo de rotação The reproducibility of VOCAL endometrial volume measurement: importance of the step rotation, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032006000100007 [Accessed 5 Aug. 2026].

Teilen und drucken

Speichern Sie den Datensatz, kopieren Sie den Permalink oder drucken Sie ihn als PDF.

Referenz exportieren

Exportieren Sie den Datensatz in gängigen Formaten für Literaturverwaltungsprogramme.

Ressourcendetails

Bibliografische Angaben zur Prüfung, ob es sich um das richtige Material handelt.

Titel
A reprodutibilidade da medida do volume endometrial por meio do VOCAL: a importância do passo de rotação The reproducibility of VOCAL endometrial volume measurement: importance of the step rotation
Autor / Mitwirkende
Wellington de Paula Martins et al
Verlag
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Erscheinungsjahr
2006
ISSN
0100-7203
ISSN
0100-7203
Sprache
Inglés

Schlagwörter

Entdecken Sie über diese Schlagwörter weitere verwandte Ressourcen.

Kopiert