Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Investigate Oblique Incident Alpha Particle Tracks on CR-39 Detector

Yasser Khlile et al · University of Mosul, College of Education for Pure Science · 2020

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A Comparative Study Between Lipid A Extracted from Salmonella typhi and Pseudomonas Aeruginosa to Demonstrate the Extent of its Stimulation of Immune System

Questa pubblicazione seriale contiene 109 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

In this paper, the nuclear track detector CR-39 with a thickness of 200 µm is divided to several pieces. The area of one piece is 1 x 1 cm2. This study has involved two parts. Fist part is without irradiated by alpha particles. The second is irradiated by alpha particles with energy E = 1.2 MeV using the 241Am radioactivity source and incident angles (0, 10, 30, 50)o. All samples etching with sodium hydroxide solution at a concentration of 6.25 N and a temperature of (70 ± 1) oC. The study included calculating track parameters and comparing them with the results of the first equation from the Track-Test program. This comparison showed that there is a good agreement between experimental results and Track-Test data for track profile.<br /> In this paper, the nuclear track detector CR-39 with a thickness of 200 µm is divided to several pieces. The area of one piece is 1 x 1 cm2. This study has involved two parts. Fist part is without irradiated by alpha particles. The second is irradiated by alpha particles with energy E = 1.2 MeV using the 241Am radioactivity source and incident angles (0, 10, 30, 50)o. All samples etching with sodium hydroxide solution at a concentration of 6.25 N and a temperature of (70 ± 1) oC. The study included calculating track parameters and comparing them with the results of the first equation from the Track-Test program. This comparison showed that there is a good agreement between experimental results and

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Y. K. E. (2020). Investigate Oblique Incident Alpha Particle Tracks on CR-39 Detector. https://doi.org/10.33899/edusj.2020.127268.1081

MLA

al, Yasser Khlile et. "Investigate Oblique Incident Alpha Particle Tracks on CR-39 Detector." 2020. https://doi.org/10.33899/edusj.2020.127268.1081.

Chicago

al, Yasser Khlile et. 2020. "Investigate Oblique Incident Alpha Particle Tracks on CR-39 Detector.". https://doi.org/10.33899/edusj.2020.127268.1081.

Harvard

al, Y. K. E. 2020, Investigate Oblique Incident Alpha Particle Tracks on CR-39 Detector, University of Mosul, College of Education for Pure Science, available at: https://doi.org/10.33899/edusj.2020.127268.1081 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Investigate Oblique Incident Alpha Particle Tracks on CR-39 Detector
Autore / collaboratori
Yasser Khlile et al
Editore
University of Mosul, College of Education for Pure Science
Anno di pubblicazione
2020
ISSN
1812-125X
ISSN
1812-125X
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato