Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Effect of Fluorescent Condensation Plates (CaWO4) on Radiation Dose Received at X-Ray.

Qusay Aldulayme et al · University of Mosul, College of Education for Pure Science · 2009

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A Comparative Study Between Lipid A Extracted from Salmonella typhi and Pseudomonas Aeruginosa to Demonstrate the Extent of its Stimulation of Immune System

Questa pubblicazione seriale contiene 109 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract<br /> The present study aims to investigate the effect of using (CaWO4) as intensifying screen on radiation dose received by patients exposed to dental investigation by x-ray. It was found that intensifying screen increases, the radiation dose from )4-6( times according to the properties of the intensifying materials used. The optical density of the x-ray film was measured by using densitometer. According to our measurements, a decrease in radiation dose was approximately 24% for the same condition .Am241 was used because its energy (59.5keV) is close to the energy of x-ray in dental radiography.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Q. A. E. (2009). Effect of Fluorescent Condensation Plates (CaWO4) on Radiation Dose Received at X-Ray. https://doi.org/10.33899/edusj.2009.57777

MLA

al, Qusay Aldulayme et. "Effect of Fluorescent Condensation Plates (CaWO4) on Radiation Dose Received at X-Ray." 2009. https://doi.org/10.33899/edusj.2009.57777.

Chicago

al, Qusay Aldulayme et. 2009. "Effect of Fluorescent Condensation Plates (CaWO4) on Radiation Dose Received at X-Ray.". https://doi.org/10.33899/edusj.2009.57777.

Harvard

al, Q. A. E. 2009, Effect of Fluorescent Condensation Plates (CaWO4) on Radiation Dose Received at X-Ray, University of Mosul, College of Education for Pure Science, available at: https://doi.org/10.33899/edusj.2009.57777 [Accessed 6 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Effect of Fluorescent Condensation Plates (CaWO4) on Radiation Dose Received at X-Ray.
Autore / collaboratori
Qusay Aldulayme et al
Editore
University of Mosul, College of Education for Pure Science
Anno di pubblicazione
2009
ISSN
1812-125X
ISSN
1812-125X
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato