Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Avaliação da maturidade pulmonar fetal pela contagem dos corpos lamelares no líquido amniótico Evaluation of fetal lung maturity by lamellar bodies counting in amniotic fluid

Beatriz Maykot Kuerten Gil et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2010

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

OBJETIVO: comparar o teste de contagem de corpos lamelares (CCL) no líquido amniótico com o teste da polarização fluorescente (PF) como parâmetro diagnóstico para avaliação da maturidade pulmonar fetal. MÉTODO: estudo transversal, analítico e controlado realizado com 60 gestantes atendidas no período de março de 2002 a dezembro de 2007. Foram colhidas amostras de líquido amniótico e realizados os testes de CCL e PF (TDxFLM II), considerados de referência, e comparados à presença ou ausência da Síndrome do Desconforto Respiratório (SDR). Foram estabelecidos valores de corte para maturidade de 30 mil corpos lamelares/µL para o teste da CCL e 55 mg/g de albumina para o PF. Foram avaliadas as características maternas e perinatais, a evolução neonatal e o desempenho dos testes diagnósticos para predição da maturidade pulmonar fetal. Na análise estatística, foram utilizadas medidas descritivas e calculados os valores referentes à sensibilidade, especificidade, valor preditivo positivo e negativo dos testes, considerando-se significativos valores de p<0,05. RESULTADOS: a idade materna variou entre 15 e 43 anos, com média de 26,6 anos. A idade gestacional variou entre 24,3 e 41,6 semanas, com média de 35,1 semanas. A Síndrome do Desconforto Respiratório foi diagnosticada em 13,3% dos neonatos. As características perinatais, como peso, índice de Apgar, incidência de SDR, foram comparadas aos resultados dos testes de CCL e PF, sendo observada uma correspondência, estatisticamente significativa (p<0,05), entre os grupos de neonatos clinicamente classificados como imaturos e maduros em ambos os testes. Os testes foram concordantes em 68,3% dos casos. Quando se comparou o teste da PF com o teste da CCL, a sensibilidade foi de 100% para ambos, e a especificidade do teste da CCL foi superior (73,1%), quando comparado com o teste de PF (51,9%). O padrão-ouro para determinação da maturidade fetal é a ocorrência da SDR. O valor preditivo positivo do teste da CCL foi superior (36,4%) quando comparado ao teste da PF (24,2%) (p<0,05), sendo que o valor preditivo negativo foi de 100% para ambos os testes. CONCLUSÕES: este estudo demonstrou que o teste da CCL apresenta 100% de sensibilidade e especificidade superior ao teste de referência (PF). Além disso, a CCL é considerada um teste rápido, acessível, barato e factível em nossa realidade, podendo ser utilizado como teste confiável na predição da maturidade pulmonar fetal.<br>PURPOSE: to compare the lamellar body number density (LBND) count in amniotic fluid using the fluorescent polarization (FP) test as a diagnostic parameter for the assessment of fetal pulmonary maturity. METHOD: this was an analytical, controlled cross-sectional study conducted on 60 pregnant women from March 2002 to December 2007. Amniotic fluid specimens were obtained by amniocentesis or at the time of caesarean section, and submitted to the LBND and FP tests (TDxFLM®, Abbott Laboratories), the latter considered to be a reference test, and compared in terms of the presence or absence of respiratory distress syndrome (RDS). Cut-off values for maturity were established at 30,000 lamellar bodies/µL for the LBND test and 55 mg/g albumin for the FP test. Maternal and perinatal characteristics and neonatal evolution were evaluated, and the performance of the diagnostic tests regarding fetal pulmonary maturity was determined. In the statistical analysis, descriptive measures were used and the sensitivity, specificity and positive and predictive values of the tests were determined with the level of significance set at p<0.05. RESULTS: maternal age ranged from 15 to 34 years (mean: 26.6 years) and gestational age ranged from 24.3 to 41.6 weeks (mean: 35.1 weeks). RDS was diagnosed in 35.1% of neonates. Perinatal characteristics such as weight, Apgar score, and RDS incidence were compared to the results of the LBND and FP tests and a significant correspondence (p<0.05) was observed between the groups of neonates clinically classified as mature and immature in both tests. The tests were concordant in 68.3% of the cases. Comparison of the PF and LBND tests revealed 100% specificity for both and a higher specificity for the LBND test (73.1% as opposed to 51.9% for the PF test). The gold standard for the determination of fetal maturity is the occurrence of RDS. The positive predictive value of the LBND test was higher (36.4%) than that of the FP test (24.2%) (p<0.05) and the negative predictive value was 100% for both tests. CONCLUSIONS: the present study demonstrated that the LBND test has 100% sensitivity and higher specificity than the reference test (FP). In addition, the LBND test is considered to be rapid, accessible, inexpensive and feasible for the Brazilian reality, and it can be used as a reliable test for the prediction of fetal pulmonary maturity.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, B. M. K. G. E. (2010). Avaliação da maturidade pulmonar fetal pela contagem dos corpos lamelares no líquido amniótico Evaluation of fetal lung maturity by lamellar bodies counting in amniotic fluid. https://doi.org/10.1590/S0100-72032010000300003

MLA

al, Beatriz Maykot Kuerten Gil et. "Avaliação da maturidade pulmonar fetal pela contagem dos corpos lamelares no líquido amniótico Evaluation of fetal lung maturity by lamellar bodies counting in amniotic fluid." 2010. https://doi.org/10.1590/S0100-72032010000300003.

Chicago

al, Beatriz Maykot Kuerten Gil et. 2010. "Avaliação da maturidade pulmonar fetal pela contagem dos corpos lamelares no líquido amniótico Evaluation of fetal lung maturity by lamellar bodies counting in amniotic fluid.". https://doi.org/10.1590/S0100-72032010000300003.

Harvard

al, B. M. K. G. E. 2010, Avaliação da maturidade pulmonar fetal pela contagem dos corpos lamelares no líquido amniótico Evaluation of fetal lung maturity by lamellar bodies counting in amniotic fluid, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032010000300003 [Accessed 5 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Avaliação da maturidade pulmonar fetal pela contagem dos corpos lamelares no líquido amniótico Evaluation of fetal lung maturity by lamellar bodies counting in amniotic fluid
Autore / collaboratori
Beatriz Maykot Kuerten Gil et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2010
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato