Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Comparação da linfocintilografia com dextrano 500 com a do fitato na pesquisa do linfonodo sentinela no câncer de mama Lymphoscintigraphy imaging study for sentinel node mapping, comparing dextran 500 with phytate, in breast cancer patients

Nilton Leite Xavier et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2005

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

OBJETIVO: comparar a acurácia de dois radiocolóides na marcação do linfonodo sentinela (LNS) por imagem. MÉTODOS: as pacientes foram incluídas no período de maio de 2002 a abril de 2004. Neste estudo duplo-cego, a paciente foi submetida duas vezes ao mesmo exame, mas com fármacos diferentes, sendo que os fármacos, tecnécio-99m-dextrano 500 (dextrano) e tecnécio-99m-fitato (fitato), foram injetados, na mama, em quatro pontos na área peritumoral e no subcutâneo superficialmente ao tumor, com volume de 2 ml, contendo de 1,0 a 1,5 mCi, em alíquotas de 0,4 ml. Para a obtenção das imagens, duas horas após a injeção do radiofármaco, usamos gama-câmera com colimador de alta resolução. A drenagem linfática axilar foi identificada em imagens radiográficas estáticas, anterior e lateral. A estatística para pares discordantes foi realizada pelo teste de MacNemar e pelo teste Z para proporções. RESULTADOS: na análise das 40 pacientes, obtiveram-se 15 pares com imagens positivas iguais, 4 pares com imagens negativas e 21 pares com imagens distintas, seja porque uma era negativa, seja porque o número de LNS marcados era diferente. A análise do desempenho quanto ao sucesso e insucesso mostrou 35 e 27 imagens positivas e 5 e 13 imagens negativas, respectivamente para o dextrano e o fitato, sendo que das negativas 4 eram comuns. O estudo estatístico pelo teste de MacNemar mostrou p=0,026, com odds ratio (OR) = 0,11 e IC 95% 0,01<OR<0,85. A taxa de sucesso foi 67,5% para o fitato e 87,5% para o dextrano 500 e a avaliação da acurácia pelos percentuais também foi significante, com p=0,032. Pela ANOVA o número de LNS apontados, foi altamente significante, com p=0,008. CONCLUSÃO: este estudo demonstra que a linfocintilografia com dextrano 500 indica linfonodos com mais freqüência que o fitato, quando usados com a mesma metodologia, na obtenção da imagem do LNS de tumores da mama.<br>PURPOSE: a case-control study comparing two radiocolloids used in scintigraphy to map the sentinel lymph nodes (SLN) in breast cancer patients. METHODS: forty patients were prospectively enrolled between May 2002 and April 2004, after signing an informed consent form. In the present double-blind study, each patient was submitted twice to the same examination, a mammary scintigraphy, one with 99mTc-dextran 500 (dextran) and the other with 99mTc-phytate (phytate), on different days. A volume of 2 ml with 1-1.5 mCi of each radiopharmaceutical, in divided aliquots, was injected in the breast parenchyma in four points around in the tumor and the subcutaneous area superficial to the tumor. The image was obtained 2 h after the injection, using a gamma camera with high-resolution collimator. The lymph nodes were identified by anterior and lateral static scintigraphic images. Statistical analysis was done with the use of McNemar and Z tests. RESULTS: in the analysis of the 40 patients, we had 15 pairs with positive identical images, 4 pairs with negative images and 21 pairs with inconsistent images, either because one of them was negative, or because the SLN numbers were different. When the protocol was opened, we found 35 and 27 positive images and 5 and 13 negative images for dextran and phytate treatment groups, respectively. Among the negative images, 4 were shared by both groups. The McNemar test, used for the statistical analysis, showed p=0.026, odds ratio (OR) = 0.11 with 95% CI 0.01 < OR < 0.85. The accuracy, evaluated by the success ratio of the SLN mapping, was 67.5% for phytate and 87.5% for dextran, with p=0.032. Analysis of variance of the SLN number in lymphoscintigraphy images showed p=0.008. CONCLUSION: these results recommend the use of dextran instead of phytate for the SLN study of breast carcinoma by scintigraphy, when the same methodology is being used.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, N. L. X. E. (2005). Comparação da linfocintilografia com dextrano 500 com a do fitato na pesquisa do linfonodo sentinela no câncer de mama Lymphoscintigraphy imaging study for sentinel node mapping, comparing dextran 500 with phytate, in breast cancer patients. https://doi.org/10.1590/S0100-72032005000600008

MLA

al, Nilton Leite Xavier et. "Comparação da linfocintilografia com dextrano 500 com a do fitato na pesquisa do linfonodo sentinela no câncer de mama Lymphoscintigraphy imaging study for sentinel node mapping, comparing dextran 500 with phytate, in breast cancer patients." 2005. https://doi.org/10.1590/S0100-72032005000600008.

Chicago

al, Nilton Leite Xavier et. 2005. "Comparação da linfocintilografia com dextrano 500 com a do fitato na pesquisa do linfonodo sentinela no câncer de mama Lymphoscintigraphy imaging study for sentinel node mapping, comparing dextran 500 with phytate, in breast cancer patients.". https://doi.org/10.1590/S0100-72032005000600008.

Harvard

al, N. L. X. E. 2005, Comparação da linfocintilografia com dextrano 500 com a do fitato na pesquisa do linfonodo sentinela no câncer de mama Lymphoscintigraphy imaging study for sentinel node mapping, comparing dextran 500 with phytate, in breast cancer patients, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032005000600008 [Accessed 5 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Comparação da linfocintilografia com dextrano 500 com a do fitato na pesquisa do linfonodo sentinela no câncer de mama Lymphoscintigraphy imaging study for sentinel node mapping, comparing dextran 500 with phytate, in breast cancer patients
Autore / collaboratori
Nilton Leite Xavier et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2005
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato