A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction

Joseph J. Bateman et al · Frontiers Media S.A · 2025

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

PurposeCurrent proton beam therapy patient-specific quality assurance (PSQA) methods rely on time-intensive phantom measurements or machine-reported parameters without independent verification. This work presents an integrated detector system for phantom-less Pencil Beam Scanning (PBS) PSQA, providing independent spot-by-spot measurements of all critical beam parameters and 3D dose reconstruction.MethodsThe integrated detector combines three separate systems: a scintillator range telescope for range and energy measurement; a CMOS pixel sensor for spot position and size verification; and a Transmission Calorimeter (TC) for beam intensity measurements. Measured parameters feed Monte Carlo simulations to reconstruct 3D dose distributions for comparison with treatment planning predictions. Validation was performed at UCLH using single spot position spread out Bragg Peak (SOBP) and 5×5×10 spot box field configurations.ResultsEnergy values obtained from range measurements showed strong correlation with DICOM values (R2> 0.998) with an accuracy of between 2.17 mm and 1.23 mm for different beam deliveries. CMOS pixel sensor measurements succeeded for single spot fields but experienced saturation at higher intensities and incomplete coverage for the larger box field. The TC demonstrated excellent dose linearity (R2 = 1.000). Monte Carlo reconstructions agreed well with reference simulations for longitudinal profiles, though lateral reconstructions proved challenging with 77% gamma pass rates (2%/2mm) for the box field.DiscussionThis proof-of-concept demonstrates feasibility of independent beam parameter verification for PBS PSQA while maintaining patient geometry. The approach offers advantages over current methods but requires resolution of energy calibration offsets and detector limitations before clinical implementation. Future work will address these challenges and expand validation to clinical treatment plans.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. J. B. E. (2025). A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction. https://doi.org/10.3389/fonc.2025.1677439

MLA

al, Joseph J. Bateman et. "A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction." 2025. https://doi.org/10.3389/fonc.2025.1677439.

Chicago

al, Joseph J. Bateman et. 2025. "A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction.". https://doi.org/10.3389/fonc.2025.1677439.

Harvard

al, J. J. B. E. 2025, A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction, Frontiers Media S.A, available at: https://doi.org/10.3389/fonc.2025.1677439 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction
Autore / collaboratori
Joseph J. Bateman et al
Editore
Frontiers Media S.A
Anno di pubblicazione
2025
ISSN
2234-943X
ISSN
2234-943X
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato