A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction

Joseph J. Bateman et al · Frontiers Media S.A · 2025

Acesso aberto disponível
Leitura rápida. Confira os dados básicos do recurso e acesse o conteúdo pelo botão principal. Esta ficha mostra apenas as informações necessárias para identificar, citar e abrir a obra.

Acesso ao recurso

Acesse o conteúdo pela opção principal ou escolha outra fonte disponível.

DOAJ DOAJ Articles
Entrar por DOAJ
Acesso principal

Acesso aberto disponível

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Abrir recurso

Resumo

Descripción general del contenido del recurso.

PurposeCurrent proton beam therapy patient-specific quality assurance (PSQA) methods rely on time-intensive phantom measurements or machine-reported parameters without independent verification. This work presents an integrated detector system for phantom-less Pencil Beam Scanning (PBS) PSQA, providing independent spot-by-spot measurements of all critical beam parameters and 3D dose reconstruction.MethodsThe integrated detector combines three separate systems: a scintillator range telescope for range and energy measurement; a CMOS pixel sensor for spot position and size verification; and a Transmission Calorimeter (TC) for beam intensity measurements. Measured parameters feed Monte Carlo simulations to reconstruct 3D dose distributions for comparison with treatment planning predictions. Validation was performed at UCLH using single spot position spread out Bragg Peak (SOBP) and 5×5×10 spot box field configurations.ResultsEnergy values obtained from range measurements showed strong correlation with DICOM values (R2> 0.998) with an accuracy of between 2.17 mm and 1.23 mm for different beam deliveries. CMOS pixel sensor measurements succeeded for single spot fields but experienced saturation at higher intensities and incomplete coverage for the larger box field. The TC demonstrated excellent dose linearity (R2 = 1.000). Monte Carlo reconstructions agreed well with reference simulations for longitudinal profiles, though lateral reconstructions proved challenging with 77% gamma pass rates (2%/2mm) for the box field.DiscussionThis proof-of-concept demonstrates feasibility of independent beam parameter verification for PBS PSQA while maintaining patient geometry. The approach offers advantages over current methods but requires resolution of energy calibration offsets and detector limitations before clinical implementation. Future work will address these challenges and expand validation to clinical treatment plans.

Como citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. J. B. E. (2025). A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction. https://doi.org/10.3389/fonc.2025.1677439

MLA

al, Joseph J. Bateman et. "A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction." 2025. https://doi.org/10.3389/fonc.2025.1677439.

Chicago

al, Joseph J. Bateman et. 2025. "A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction.". https://doi.org/10.3389/fonc.2025.1677439.

Harvard

al, J. J. B. E. 2025, A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction, Frontiers Media S.A, available at: https://doi.org/10.3389/fonc.2025.1677439 [Accessed 6 Aug. 2026].

Compartilhar e imprimir

Salve a ficha, copie o link permanente ou imprima em PDF.

Exportar referência

Exporte o registro nos formatos mais comuns para usar em um gerenciador bibliográfico.

Detalhes do recurso

Informações bibliográficas para confirmar que este é o material correto.

Título
A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction
Autor / colaboradores
Joseph J. Bateman et al
Editora
Frontiers Media S.A
Ano de publicação
2025
ISSN
2234-943X
ISSN
2234-943X
Idioma
Inglés

Assuntos

Explore recursos relacionados a partir destes assuntos.

Copiado