Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%

Stacey Ness et al · Rockefeller University Press · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A 5-Year-Old Female with Neutropenia and Compound Heterozygous Variants in CXCR2

Questa pubblicazione seriale contiene 232 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

IntroductionIt is imperative to minimize protein aggregates in commercial intravenous immunoglobulin (IVIG) therapy as they have been implicated in adverse events and can enhance immunogenicity for patients receiving IVIG therapy. Shear stress, agitation, mixing speed, and filtration can impact aggregate formation during the manufacturing process, while shipping conditions and temperature excursions may contribute after manufacturing. A study was conducted to assess the impact of agitation on the molecular size distribution of Alyglo (immune globulin intravenous, human-stwk, 10% [IVIG-stwk 10%]).Methods10 mL of IVIG-stwk 10% was dispensed into sterile washed vials, which were stoppered and sealed. Vials were then placed on a Green SSeriker shaker (Vision Science), and agitation started at 50 rpm in an upright position at a temperature of between 20 and 25°C to induce mechanical stress. On days 0, 1, 3, and 11, samples were withdrawn and diluted 1:16 with saline for analysis. The molecular size distribution of monomers, dimers, high-molecular weight aggregates, and fragments was quantified using size-exclusion high-performance liquid chromatography (SE-HPLC). For SE-HPLC, chromatographic separations were performed using a size exclusion column (TSKgel G3000SW) using a sample size of 50 mcL and a flow rate of 0.5 mL/min at a detection wavelength of 280 nm.ResultsThe monomer + dimer percentage for IVIG-stwk 10% on day 0 was 99.576%; day 1 99.582%; day 3 99.591%; day 11 99.526%. The percentage of polymers and fragments remained below their respective validated limits of quantitation (0.3% and 0.5%) for each time point.ConclusionMechanical agitation for up to 11 days shows minimal impact on IVIG-stwk 10% molecular size distribution. A very high percentage of monomers and dimers remained throughout the duration of the study, compared to polymers and fragments below quantifiable limits. Further assessments, more analogous to real-world conditions, along with additional measurements of opacity and particle size across multiple lots to assess variability, are warranted.Tabular data are included as downloadable supplement files.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. N. E. (2026). Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%. https://doi.org/10.70962/CIS2026abstract.58

MLA

al, Stacey Ness et. "Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%." 2026. https://doi.org/10.70962/CIS2026abstract.58.

Chicago

al, Stacey Ness et. 2026. "Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%.". https://doi.org/10.70962/CIS2026abstract.58.

Harvard

al, S. N. E. 2026, Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%, Rockefeller University Press, available at: https://doi.org/10.70962/CIS2026abstract.58 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%
Autore / collaboratori
Stacey Ness et al
Editore
Rockefeller University Press
Anno di pubblicazione
2026
ISSN
3065-8993
ISSN
3065-8993
Lingua
Inglés
Copiato