Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography

Joshua Hutchings et al · International Union of Crystallography · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

The Volta phase plate (VPP) can enhance low-frequency phase contrast in cryo-electron microscopy (cryo-EM) and cryo-electron tomography (cryo-ET), but its impact on tomogram alignment has not been systematically assessed. Using sub-2 Å single-particle analysis (SPA) and analytical contrast transfer function (CTF) modeling, we show that despite high-frequency information loss and moderate signal damping, the VPP enhances signal in low-frequency bands that are crucial for tilt-series alignment. We show that VPP tomograms exhibit increased contrast and remain higher in contrast post denoising, for thick and crowded specimens. Quantitative comparison of tomograms acquired with and without the VPP shows improved tilt-axis orientation measurements and a higher fraction of tomograms amenable to local tilt-series alignment. Although acquisition with the VPP yields lower subtomogram averaging (STA) resolution, these results show that the primary benefits of the VPP for cryo-ET are contrast enhancement and improved tilt-series alignment robustness, which are crucial for studying cellular ultrastructure and protein organization in crowded environments, where STA at moderate resolutions remains valuable.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. H. E. (2026). Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography. https://doi.org/10.1107/S2052252526002575

MLA

al, Joshua Hutchings et. "Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography." 2026. https://doi.org/10.1107/S2052252526002575.

Chicago

al, Joshua Hutchings et. 2026. "Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography.". https://doi.org/10.1107/S2052252526002575.

Harvard

al, J. H. E. 2026, Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography, International Union of Crystallography, available at: https://doi.org/10.1107/S2052252526002575 [Accessed 10 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography
Autore / collaboratori
Joshua Hutchings et al
Editore
International Union of Crystallography
Anno di pubblicazione
2026
ISSN
2052-2525
ISSN
2052-2525
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato