Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo de revista

Characterizing Pulmonary Gas Exchange in Inborn Errors of Immunity Using Hyperpolarized Xenon MRI

Ernest Hoptioncann et al · Rockefeller University Press · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A 5-Year-Old Female with Neutropenia and Compound Heterozygous Variants in CXCR2

Questa pubblicazione seriale contiene 232 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

RationaleInborn errors of immunity (IEIs) predispose individuals to recurrent respiratory infections and immune dysregulation, which together can drive inflammatory lung complications, including interstitial lung disease and thickening of the interstitial (alveolar–capillary) membrane. These changes are often subtle and may not be captured by conventional lung function testing. Hyperpolarized 129Xe MRI (XeMRI) is a novel, noninvasive technique that quantifies regional gas exchange by leveraging xenon’s solubility in distinct pulmonary compartments: airspaces (Gas), interstitial membrane (Mem), and capillary red blood cells (RBC).ObjectivesEvaluate whether XeMRI can detect differences in pulmonary gas exchange in people with IEIs (pwIEIs) by comparing gas exchange ratios (Mem/Gas, RBC/Gas, and RBC/Mem) with healthy controls (HCs).MethodsXeMRI was performed using a four-echo, 3D radial spectroscopic sequence to quantify compartment-specific signals (Gas, Mem, and RBC). All scans were acquired during a standardized breath-hold following inhalation of a hyperpolarized 129Xe/N2 mixture. Carbon monoxide transfer coefficients (Kco), reported as GLI z-scores, were obtained from routine testing within three months of imaging for qualitative comparison. Group differences between pwIEIs and HCs were assessed using two-sided Mann–Whitney U tests for Mem/Gas (xenon uptake in membrane relative to gas), RBC/Gas (xenon uptake in RBCs relative to gas), and RBC/Mem (xenon uptake in RBCs relative to membrane).ResultsSeventeen pwIEIs (3F/14M; median age 28 years [Q1–Q3: 16–37]) and ten HC (3F/7M; median age 22 years [Q1–Q3: 15–23]) were included; HC recruitment is ongoing. Mem/Gas was significantly higher in pwIEIs than in HCs (0.0159 vs. 0.0134, p = 0.0459), while RBC/Mem was significantly lower in pwIEIs (0.4124 vs. 0.4624, p = 0.0355). RBC/Gas did not differ between groups (0.0057 vs. 0.0057, p=0.9019). Four pwIEIs (23.5%) had reduced Kco values (z < 1.3, <10th percentile); however, Kco showed no clear relationship with any gas-exchange ratiosConclusions:pwIEIs, many of whom had normal lung function tests, showed increased xenon signal within the interstitial compartment with reduced transfer into the blood relative to the membrane signal. This pattern is consistent with mild interstitial pathology and suggests that XeMRI may provide a sensitive, noninvasive method for detecting interstitial pulmonary involvement in pwIEIs.Figure 1.XeMRI-derived gas-exchange ratios in people with inborn errors of immunity and healthy controls. Violin plots show group differences in hyperpolarized XeMRI ratios: (A) RBC/Gas, (B) RBC/Mem, and (C) Mem/Gas. People with inborn errors of immunity had a higher Mem/Gas ratio (p=0.0459) and lower RBC/Mem ratio (p = 0.0355) compared to healthy controls, with no difference in RBC/Gas ratio (p=0.9019). White-filled points denote individuals with reduced Kco (z < −1.3, <10th percentile). RBC, red blood cell; Mem, interstitial (alveolar-capillary) membrane; Gas, airspaces; HC, healthy controls; IEI, inborn error of immunity; Kco, carbon monoxide transfer coefficient.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, E. H. E. (2026). Characterizing Pulmonary Gas Exchange in Inborn Errors of Immunity Using Hyperpolarized Xenon MRI. https://doi.org/10.70962/CIS2026abstract.38

MLA

al, Ernest Hoptioncann et. "Characterizing Pulmonary Gas Exchange in Inborn Errors of Immunity Using Hyperpolarized Xenon MRI." 2026. https://doi.org/10.70962/CIS2026abstract.38.

Chicago

al, Ernest Hoptioncann et. 2026. "Characterizing Pulmonary Gas Exchange in Inborn Errors of Immunity Using Hyperpolarized Xenon MRI.". https://doi.org/10.70962/CIS2026abstract.38.

Harvard

al, E. H. E. 2026, Characterizing Pulmonary Gas Exchange in Inborn Errors of Immunity Using Hyperpolarized Xenon MRI, Rockefeller University Press, available at: https://doi.org/10.70962/CIS2026abstract.38 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Characterizing Pulmonary Gas Exchange in Inborn Errors of Immunity Using Hyperpolarized Xenon MRI
Autore / collaboratori
Ernest Hoptioncann et al
Editore
Rockefeller University Press
Anno di pubblicazione
2026
ISSN
3065-8993
ISSN
3065-8993
Lingua
Inglés
Copiato