Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

The anatomical bone corridor study of schanz screw placement in adolescent pelvic ring fractures via three-dimensional CT

Xiang Ren et al · Frontiers Media S.A · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

PurposeTo define the anatomical boundaries of potential safe corridors for the placement of Schanz screws during external fixation of unstable pelvic fractures in normally developed adolescents aged 11–14 years.Patients and methodsPelvic CT scans of 34 patients (18 males, 16 females; mean age 12 years) were reconstructed into 3D models using Mimics 21.0. A supine coordinate system was defined using anatomical landmarks, including the anterior superior iliac spine (ASIS), posterior superior iliac spine (PSIS), and anterior inferior iliac spine (AIIS). Cross-sectional measurements of the iliac wing and supra-acetabular corridors were performed, simulating 4 mm Schanz screw trajectories and documenting entry points, angles, and corridor dimensions.ResultsIliac Wing Corridor: The morphology transitioned from proximal rectangular to mid-corridor dumbbell-shaped, with distal funnel-like narrowing. Anterior/posterior corridor lengths measured 54.2–58.6 mm and 68.1–73.1 mm (95% CI), respectively. Screw I1 entry (16.9–18.7 mm posterior to ASIS; 95% CI) required horizontal/sagittal angles of 22.5–25.8° and 53.7–61.2° (95% CI). Screw I2 entry (49.4–53.6 mm posterior to ASIS; 95% CI) necessitated horizontal/sagittal angles of 21.5–25.1° and 61.3–66.1° (95% CI).Supra-acetabular corridorS-shaped with mid-corridor constriction. The longest trajectory (116.7–125.3 mm; 95% CI) aligned with the AIIS-PSIS central plane, while the shortest (95.9–105.9 mm; 95% CI) occurred in the periacetabular region. Screw A insertion via the AIIS-PSIS plane required horizontal/sagittal angles of 58.2–61.3° and 23.0–25.6° (95% CI), respectively.ConclusionBoth iliac wing and supra-acetabular corridors demonstrated safe accommodation of 4 mm Schanz screws in this age group. Adherence to predefined entry points and angles is critical to minimize perforation risk and optimize fixation stability. Patient-specific computer-assisted preoperative surgical planning is particularly well-suited for adolescents in enhancing surgical safety.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, X. R. E. (2026). The anatomical bone corridor study of schanz screw placement in adolescent pelvic ring fractures via three-dimensional CT. https://doi.org/10.3389/fsurg.2026.1816272

MLA

al, Xiang Ren et. "The anatomical bone corridor study of schanz screw placement in adolescent pelvic ring fractures via three-dimensional CT." 2026. https://doi.org/10.3389/fsurg.2026.1816272.

Chicago

al, Xiang Ren et. 2026. "The anatomical bone corridor study of schanz screw placement in adolescent pelvic ring fractures via three-dimensional CT.". https://doi.org/10.3389/fsurg.2026.1816272.

Harvard

al, X. R. E. 2026, The anatomical bone corridor study of schanz screw placement in adolescent pelvic ring fractures via three-dimensional CT, Frontiers Media S.A, available at: https://doi.org/10.3389/fsurg.2026.1816272 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
The anatomical bone corridor study of schanz screw placement in adolescent pelvic ring fractures via three-dimensional CT
Autore / collaboratori
Xiang Ren et al
Editore
Frontiers Media S.A
Anno di pubblicazione
2026
ISSN
2296-875X
ISSN
2296-875X
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato