Experimental Study to Evaluate the Load-Bearing Capacity of Autoclaved Aerated Concrete Block Walls

Sarra’a Dhiya’a Jaafer et al · Mustansiriyah University/College of Engineering · 2026

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

It is common to use Autoclaved Aerated Concrete (AAC) blocks in the construction of partition walls and infills because of their distinctive properties, including ease of work, energy conservation, and enhanced sustainability. Experiments for the strength evaluation of AAC load-bearing walls are still limited. This paper presents an experimental study of the behavior of AAC blocks as load-bearing walls under static loads up to failure. Due to the difficulty of using the direct contact method to measure and monitor deformations in walls, the Digital Image Correlation (DIC) method was used to obtain the required data throughout the test. Eight specimens of confined walls were tested to study the effect of the thickness of the block, type of bonding material, and type of plastering on the wall strength and failure modes. ‎ The results showed that the smaller the thickness of the AAC block, the greater the strength of the wall. Also, using adhesive mortar leads to the cohesion of the wall and increases its load-bearing capacity better than using cement-sand or gypsum mortar. In addition, strengthening the plastering with steel wire meshes showed superior performance in wall behavior in improving cracking resistance and ultimate loads.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. D. J. E. (2026). Experimental Study to Evaluate the Load-Bearing Capacity of Autoclaved Aerated Concrete Block Walls. https://doi.org/10.31272/jeasd.2452

MLA

al, Sarra’a Dhiya’a Jaafer et. "Experimental Study to Evaluate the Load-Bearing Capacity of Autoclaved Aerated Concrete Block Walls." 2026. https://doi.org/10.31272/jeasd.2452.

Chicago

al, Sarra’a Dhiya’a Jaafer et. 2026. "Experimental Study to Evaluate the Load-Bearing Capacity of Autoclaved Aerated Concrete Block Walls.". https://doi.org/10.31272/jeasd.2452.

Harvard

al, S. D. J. E. 2026, Experimental Study to Evaluate the Load-Bearing Capacity of Autoclaved Aerated Concrete Block Walls, Mustansiriyah University/College of Engineering, available at: https://doi.org/10.31272/jeasd.2452 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Experimental Study to Evaluate the Load-Bearing Capacity of Autoclaved Aerated Concrete Block Walls
Autore / collaboratori
Sarra’a Dhiya’a Jaafer et al
Editore
Mustansiriyah University/College of Engineering
Anno di pubblicazione
2026
ISSN
2520-0917
ISSN
2520-0917
Lingua
ara

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato