Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Structural Efficiency and Embodied Carbon Assessment of Pre-Engineered Versus Conventional Steel Beams

Riza Suwondo et al · Mustansiriyah University/College of Engineering · 2026

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

The increased focus on the reduction of greenhouse gas emissions in the building and construction sector has heightened the demand for structural systems that reduce both material and embodied carbon. Pre-engineered building (PEB) systems using tapered built-up steel beams could potentially offer a viable alternative to traditional hot-rolled prismatic sections by better matching and aligning the sectional capacity and the bending demand. However, there are still a limited number of studies that perform comparative analyses integrating structural and environmental impact. This study assessed the structural efficiency and embodied carbon of pre-engineered and conventional steel beams over spans of 6 to 20 m for fixed-end and pinned-end boundary conditions. Structural design was performed in accordance with AISC 360-16, and embodied carbon was assessed for life cycle modules A1–A5 following BS EN 15978. The results indicate that tapered built-up beams achieve higher utilisation ratios and smaller effective section sizes, particularly for short and intermediate spans. Life-cycle assessment shows that pre-engineered beams reduce embodied carbon by approximately 10–25% compared with conventional beams, primarily owing to their lower steel mass. These findings demonstrate that tapered built-up beams offer both structural and environmental advantages in the investigated design context.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, R. S. E. (2026). Structural Efficiency and Embodied Carbon Assessment of Pre-Engineered Versus Conventional Steel Beams. https://doi.org/10.31272/jeasd.3791

MLA

al, Riza Suwondo et. "Structural Efficiency and Embodied Carbon Assessment of Pre-Engineered Versus Conventional Steel Beams." 2026. https://doi.org/10.31272/jeasd.3791.

Chicago

al, Riza Suwondo et. 2026. "Structural Efficiency and Embodied Carbon Assessment of Pre-Engineered Versus Conventional Steel Beams.". https://doi.org/10.31272/jeasd.3791.

Harvard

al, R. S. E. 2026, Structural Efficiency and Embodied Carbon Assessment of Pre-Engineered Versus Conventional Steel Beams, Mustansiriyah University/College of Engineering, available at: https://doi.org/10.31272/jeasd.3791 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Structural Efficiency and Embodied Carbon Assessment of Pre-Engineered Versus Conventional Steel Beams
Autore / collaboratori
Riza Suwondo et al
Editore
Mustansiriyah University/College of Engineering
Anno di pubblicazione
2026
ISSN
2520-0917
ISSN
2520-0917
Lingua
ara

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato