Advanced dose calculation strategies for clinical linear accelerators: a systematic review

Ali H. D. Alshehri et al · Frontiers Media S.A · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

BackgroundDelivering accurate radiation doses in heterogeneous tissues is critical in radiotherapy, yet conventional algorithms often lose accuracy in complex scenarios. Monte Carlo (MC) simulation offers a high-fidelity approach, but routine clinical use has historically been limited by computation time.PurposeThis systematic review evaluates the clinical relevance of advanced MC-based dose-calculation strategies for linear accelerators (LINACs), with emphasis on developments from 2010 to 2025 that improve dose accuracy and workflow efficiency, particularly through GPU acceleration and artificial intelligence (AI).MethodsFollowing the PRISMA 2020 guideline, PubMed, Scopus, and Web of Science were searched. The search identified 467 records; after deduplication, 312 were screened, and 17 eligible studies were included across Varian-, Elekta-, and Siemens-associated platforms. Data were extracted on simulation techniques, clinical application, and performance outcomes. Study quality was appraised using a predefined four-domain framework informed by the AAPM TG-268 RECORDS checklist, assessing methodological rigor, validation completeness, clinical relevance, and uncertainty analysis. Data synthesis followed the Synthesis Without Meta-analysis (SWiM) guidance.ResultsMC-based dose calculations consistently outperformed or matched conventional algorithms in small-field, heterogeneity-rich, and magnetic-field scenarios. GPU implementations achieved 50--2500x speed improvements with less than 1% reported dose deviation. AI applications were used mainly to reduce noise and computation time. Elekta’s Monaco TPS includes a clinically validated fast MC engine, whereas Varian-associated workflows more commonly use MC for independent quality assurance. Studies involving the Elekta Unity MR-Linac confirmed accurate modeling of magnetic-field effects. Only one included study addressed a Siemens LINAC platform.ConclusionsAccelerated MC strategies now permit accurate and efficient dose calculation that may support routine clinical workflows. However, direct evidence linking these dosimetric gains to improved clinical outcomes remains limited.Systematic review registrationhttps://osf.io/ftnbs, identifier 10.17605/OSF.IO/FTNBS.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. H. D. A. E. (2026). Advanced dose calculation strategies for clinical linear accelerators: a systematic review. https://doi.org/10.3389/fonc.2026.1790425

MLA

al, Ali H. D. Alshehri et. "Advanced dose calculation strategies for clinical linear accelerators: a systematic review." 2026. https://doi.org/10.3389/fonc.2026.1790425.

Chicago

al, Ali H. D. Alshehri et. 2026. "Advanced dose calculation strategies for clinical linear accelerators: a systematic review.". https://doi.org/10.3389/fonc.2026.1790425.

Harvard

al, A. H. D. A. E. 2026, Advanced dose calculation strategies for clinical linear accelerators: a systematic review, Frontiers Media S.A, available at: https://doi.org/10.3389/fonc.2026.1790425 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Advanced dose calculation strategies for clinical linear accelerators: a systematic review
Autore / collaboratori
Ali H. D. Alshehri et al
Editore
Frontiers Media S.A
Anno di pubblicazione
2026
ISSN
2234-943X
ISSN
2234-943X
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato