← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Assessment of the mechanical performance of a novel CT-linac treatment couch

Linyi Shen et al · Frontiers Media S.A · 2026

Acceso abierto disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Acceso abierto disponible

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Abrir recurso

Resumen

Descripción general del contenido del recurso.

PurposeThis study aims to systematically evaluate the mechanical performance of the novel treatment couch for the uLinac VisionaryTx CT-Linac (United Imaging Healthcare, China).Materials and methodsQuality assurance protocols were developed by integrating AAPM TG-142 and TG-66 guidelines. The following key parameters were assessed: (1) couch top movement accuracy, including translational/rotational precision and perpendicularity to the CT imaging plane; (2) couch top rigidity under varying loads (0–135 kg) and extensions; (3) couch base movement accuracy, covering longitudinal travel reproducibility and rotational homing; (4) efficacy of the laser rangefinder-based sag correction and the stability of the rangefinder itself; and (5) comprehensive end-to-end evaluation of IGRT workflows to determine the overall impact of couch mechanical performance on delivery accuracy. All tests were conducted under clinically representative loaded conditions.ResultsThe couch top demonstrated high accuracy in translational movement (≤ 0.5 mm), rotation (< 0.12°), and perpendicularity relative to the CT imaging plane. Under maximum load, the couch top showed a sag of 4.1 mm, demonstrating superior rigidity to a dedicated CT simulator while being slightly less rigid than conventional linac couches. The couch base achieved precise longitudinal movement (≤ 1 mm) and rotational homing accuracy (< 0.1°). The laser rangefinder-based correction method achieved good agreement between calculated and measured height variations (deviation < 0.6 mm) with excellent stability in both angular and distance measurements. End-to-end tests verified sub-millimeter (0.5 mm) and sub-degree (0.5°) accuracy for IGRT workflows across various loading conditions.ConclusionThe novel CT linac couch system (uLinac VisionaryTx) exhibits exceptional mechanical performance and fully satisfies the precision requirements for CT acquisition, image guidance, and setup error correction.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, L. S. E. (2026). Assessment of the mechanical performance of a novel CT-linac treatment couch. https://doi.org/10.3389/fonc.2026.1773010

MLA

al, Linyi Shen et. "Assessment of the mechanical performance of a novel CT-linac treatment couch." 2026. https://doi.org/10.3389/fonc.2026.1773010.

Chicago

al, Linyi Shen et. 2026. "Assessment of the mechanical performance of a novel CT-linac treatment couch.". https://doi.org/10.3389/fonc.2026.1773010.

Harvard

al, L. S. E. 2026, Assessment of the mechanical performance of a novel CT-linac treatment couch, Frontiers Media S.A, available at: https://doi.org/10.3389/fonc.2026.1773010 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Assessment of the mechanical performance of a novel CT-linac treatment couch
Autor / colaboradores
Linyi Shen et al
Editorial
Frontiers Media S.A
Año de publicación
2026
ISSN
2234-943X
ISSN
2234-943X
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado