Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Anatomically constrained volumetric smoothing enhances fMRI reliability while avoiding smoothing artifacts

David G. Ellis et al · Frontiers Media S.A · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

IntroductionSmoothing fMRI data prior to analysis is a fundamental and widely used technique to increase sensitivity. Unconstrained smoothing can also reduce the spatial specificity of the analysis by introducing artifacts in the data. This study tested the effects of smoothing on the reliability and accuracy of both task fMRI and resting state data. The effects of unconstrained smoothing were compared to those of an anatomically constrained smoothing method, which prevents smoothing across the white and gray matter surfaces of the cortex.MethodsUnconstrained Gaussian smoothing and anatomically constrained smoothing were applied to simulated data, a sensory task fMRI dataset, a precision fMRI motor task mapping dataset, and a resting state fMRI dataset. Smoothing-related artifacts were tested for and compared between the smoothing methods, and the effects of the smoothing methods on the reliability and accuracy were measured.ResultsIn the experiments with simulated data, unconstrained Gaussian smoothing demonstrated decreased accuracy and increased white matter activation compared to constrained smoothing. In the sensory task activation analysis, both Gaussian and constrained smoothing increased the reliability of the sensory task fMRI activations, but Gaussian smoothing increased the percentage of active voxels in the white matter relative to constrained smoothing (p < 0.001). Relative to constrained smoothing, Gaussian smoothing with FWHM > 3 mm also decreased the accuracy of motor mapping results from individual sessions to the precision maps (p < 0.001). With cluster significance thresholding, mean false positive voxel percentages remained below 5% for both methods across the tested kernel widths. Both Gaussian and constrained smoothing demonstrated a biasing effect on the resting state connectivity of nearby regions and on the graph theory metrics of the functional connectomes.ConclusionThis study showed that unconstrained Gaussian smoothing spreads activation across cortical boundaries, increases white matter activation, and biases graph theory connectivity metrics. Anatomically constrained smoothing reduced some of these smoothing artifacts while still increasing reliability and may be a reasonable alternative to unconstrained Gaussian smoothing.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, D. G. E. E. (2026). Anatomically constrained volumetric smoothing enhances fMRI reliability while avoiding smoothing artifacts. https://doi.org/10.3389/fnimg.2026.1753534

MLA

al, David G. Ellis et. "Anatomically constrained volumetric smoothing enhances fMRI reliability while avoiding smoothing artifacts." 2026. https://doi.org/10.3389/fnimg.2026.1753534.

Chicago

al, David G. Ellis et. 2026. "Anatomically constrained volumetric smoothing enhances fMRI reliability while avoiding smoothing artifacts.". https://doi.org/10.3389/fnimg.2026.1753534.

Harvard

al, D. G. E. E. 2026, Anatomically constrained volumetric smoothing enhances fMRI reliability while avoiding smoothing artifacts, Frontiers Media S.A, available at: https://doi.org/10.3389/fnimg.2026.1753534 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Anatomically constrained volumetric smoothing enhances fMRI reliability while avoiding smoothing artifacts
Autore / collaboratori
David G. Ellis et al
Editore
Frontiers Media S.A
Anno di pubblicazione
2026
ISSN
2813-1193
ISSN
2813-1193
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato