Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure

Preston Harrison BS et al · SAGE Publishing · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Category: Midfoot/Forefoot, Bunion Diabetes Keywords: Ankle, Degenerative, Hindfoot Deformity Introduction/Purpose: Intraoperative fluoroscopy has become essential in orthopedic surgery, particularly with the rise of minimally invasive surgery (MIS) techniques. Despite the advantages of minimally invasive foot and ankle surgery, it raises concerns about radiation exposure to both patients and surgical staff. The purpose of this study was to evaluate fluoroscopy time and radiation dose (cumulative air kerma) associated with open versus MIS bunion correction, comparing the open modified Lapidus procedure and the minimally invasive distal first metatarsal transverse osteotomy and akin osteotomy (META). It was hypothesized that the META procedure would be associated with increased radiation dose and fluoroscopy time compared to the open modified Lapidus procedure. Methods: A retrospective review was conducted for patients who underwent bunion surgery between January 2021 and June 2025 by two fellowship-trained orthopedic foot and ankle surgeons at a single academic institution. A total of 294 patients met inclusion criteria. Of these, 258 patients underwent a META procedure and 36 underwent an open modified Lapidus procedure. Fluoroscopy time (minutes) and radiation dose (mGy) were compared between groups. Results: A mean fluoroscopy time of 2.13±1.27 (range, 0.06-7.05) minutes and a radiation dose of 2.02±1.30 (range, 0.05-7.52) mGy were observed in the META cohort. An average fluoroscopy time of 1.63±1.83 (range, 0.08-7.70) minutes and a radiation dose of 1.31±1.43 (range, 0.07-5.98) mGy were observed in the open modified Lapidus cohort. There was no significant difference in fluoroscopy time between cohorts (p=0.123), however the META group demonstrated a higher radiation dose than the open modified Lapidus group (p=0.007). Conclusion: The META procedure had a significantly higher radiation dose compared to the open modified Lapidus procedure, though both remain substantially below the International Commission on Radiological Protection (ICRP) recommended occupational exposure of less than 20.00 mSv per year. Despite the META procedure generating an average radiation dose of 2.02 mGy per case, surgeons receive only 0.50% of the dose, thus, nearly 1,980 procedures would be required to exceed the 20.00 mSv annual occupational limit. These findings suggest that concerns about radiation exposure should not necessarily deter providers from performing the META technique for bunion correction.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, P. H. B. E. (2026). Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure. https://doi.org/10.1177/2473011426S00047

MLA

al, Preston Harrison BS et. "Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure." 2026. https://doi.org/10.1177/2473011426S00047.

Chicago

al, Preston Harrison BS et. 2026. "Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure.". https://doi.org/10.1177/2473011426S00047.

Harvard

al, P. H. B. E. 2026, Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure, SAGE Publishing, available at: https://doi.org/10.1177/2473011426S00047 [Accessed 5 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure
Autore / collaboratori
Preston Harrison BS et al
Editore
SAGE Publishing
Anno di pubblicazione
2026
ISSN
2473-0114
ISSN
2473-0114
Lingua
Inglés
Copiato