Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Evaluation of Changes in Intracranial Pressure in Patients Undergoing Weaning from Mechanical Ventilation Using Optic Nerve Sheath Diameter Measurement

Şamil Yurt et al · Van Yuzuncu Yil University, School of Medicine · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

INTRODUCTION: Aim is to investigate changes in intracranial pressure (ICP) during the weaning process by comparing continuous positive airway pressure (CPAP) and T-piece spontaneous breathing trials using serial optic nerve sheath diameter (ONSD) measurements by ultrasonography. METHODS: This prospective, single center study included 40 mechanically ventilated adult intensive care patients undergoing weaning. Patients were allocated to either a CPAP group (n=20) or a T-piece group (n=20). ONSD, mean arterial pressure, and rapid shallow breathing index were (RSBI) measured at predefined stages during weaning and one hour after extubation. Changes in repeated measurements and correlations between sequential measurement differences and time intervals were analyzed. RESULTS: ONSD values increased progressively during the weaning process in both groups, with a more pronounced increase observed during T-piece trials. ONSD decreased after extubation, particularly in the CPAP group. Within-group changes in ONSD were statistically significant (p<0.001). No significant differences were observed between groups regarding weaning success or RSBI changes. A significant positive correlation was identified between the change in ONSD and the duration between measurements in the T-piece group after extubation (r=0.453, p=0.045). No significant differences in ONSD were found between patients with successful and unsuccessful weaning. DISCUSSION AND CONCLUSION: T-piece spontaneous breathing trials are associated with greater increases in ONSD, suggesting higher ICP during the weaning process. Serial ONSD measurement may be a useful non-invasive tool for monitoring ICP, particularly in patients at risk of intracranial hypertension during weaning.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Ş. Y. E. (2026). Evaluation of Changes in Intracranial Pressure in Patients Undergoing Weaning from Mechanical Ventilation Using Optic Nerve Sheath Diameter Measurement. https://doi.org/10.5505/vmj.2026.13007

MLA

al, Şamil Yurt et. "Evaluation of Changes in Intracranial Pressure in Patients Undergoing Weaning from Mechanical Ventilation Using Optic Nerve Sheath Diameter Measurement." 2026. https://doi.org/10.5505/vmj.2026.13007.

Chicago

al, Şamil Yurt et. 2026. "Evaluation of Changes in Intracranial Pressure in Patients Undergoing Weaning from Mechanical Ventilation Using Optic Nerve Sheath Diameter Measurement.". https://doi.org/10.5505/vmj.2026.13007.

Harvard

al, Ş. Y. E. 2026, Evaluation of Changes in Intracranial Pressure in Patients Undergoing Weaning from Mechanical Ventilation Using Optic Nerve Sheath Diameter Measurement, Van Yuzuncu Yil University, School of Medicine, available at: https://doi.org/10.5505/vmj.2026.13007 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Evaluation of Changes in Intracranial Pressure in Patients Undergoing Weaning from Mechanical Ventilation Using Optic Nerve Sheath Diameter Measurement
Autore / collaboratori
Şamil Yurt et al
Editore
Van Yuzuncu Yil University, School of Medicine
Anno di pubblicazione
2026
ISSN
2587-0351
ISSN
2587-0351
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato