Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk

PEI Maolin et al · Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Direct-drive wind farms usually trip all wind turbines to ensure power grid security when facing sub/super-synchronous oscillation risks. Tripping the entire wind farm not only seriously damages the production operation of the wind farm, but also causes a large impact on the power grid, which is an emergency measure that has to be taken after the situation escalates. To address this problem, this paper proposes a wide-frequency measurement device assisted power regulation and generator tripping control strategy for direct-drive wind farms, to achieve early warning and rapid suppression of sub/super-synchronous oscillation accidents. The wind farm pays attention to events such as lightning tripping in the regional power grid that may induce oscillations at any time. When receiving an event report, the wind farm immediately enters a pre-warning state and adjusts the power of each wind turbine according to the pre-action strategy to enter a low-inducing state, while the wide-frequency measurement device enters an emergency state to monitor whether the wind farm has sub/super-synchronous oscillations. When oscillations are detected, the wind farm defines the tripping intensity index according to the distance between each wind turbine and the grid-connected point and the power of each wind turbine, and executes the tripping strategy for some wind turbines to achieve oscillation elimination. This paper establishes relevant simulation examples to verify the feasibility and effectiveness of the control strategy. The simulation results show that the proposed power regulation and generator tripping control strategy achieves the suppression of oscillations in direct-drive wind farms, while avoiding the tripping of all wind turbines in the wind farm, reducing the impact on the power grid.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, P. M. E. (2026). Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk. https://doi.org/10.19753/j.issn1001-1390.2026.03.014

MLA

al, PEI Maolin et. "Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk." 2026. https://doi.org/10.19753/j.issn1001-1390.2026.03.014.

Chicago

al, PEI Maolin et. 2026. "Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk.". https://doi.org/10.19753/j.issn1001-1390.2026.03.014.

Harvard

al, P. M. E. 2026, Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk, Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co, Ltd, available at: https://doi.org/10.19753/j.issn1001-1390.2026.03.014 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk
Autore / collaboratori
PEI Maolin et al
Editore
Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd
Anno di pubblicazione
2026
ISSN
1001-1390
ISSN
1001-1390
Lingua
zho

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato