Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network

HE Jianbo et al · Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

The occurrence of tree-contact single-phase-to-ground fault (TSF) poses a potential threat to the stable operation of power lines, and in severe cases, may result in wild fire. The development of TSF is influenced by crucial factors such as temperature and moisture content; however, the precise process and mechanism through which they impact failure remain unclear. This paper takes naturally growing pine trees as the experimental object and conducts a TSF experimental study. Based on the experimental data, it analyzes the impact of temperature and tree moisture content on the transition resistance of trees during TSF, and establishes an equivalent model of TSF transition resistance that takes into account the temperature and the moisture content of trees. The average relative error between model prediction and experimental measurement is less than 10%, validating the effectiveness of the model. The results show that the current heating of TSF will cause the water vapor inside the branches to evaporate into the interlayer between the bark and the trunk, which in turn affects the leakage current flow path and forms a carbonization channel on the interlayer. The distribution of moisture content caused by local heating and water vapor evaporation in the current channel is the main factor affecting the leakage current and transition resistance changes of TSF. The refined model diminishes its reliance on traditional empirical parameters and boasts enhanced alignment with experimental measurement data, offering valuable insight into the mechanisms underlying fault progression.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. J. E. (2026). Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network. https://doi.org/10.19753/j.issn1001-1390.2026.03.011

MLA

al, HE Jianbo et. "Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network." 2026. https://doi.org/10.19753/j.issn1001-1390.2026.03.011.

Chicago

al, HE Jianbo et. 2026. "Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network.". https://doi.org/10.19753/j.issn1001-1390.2026.03.011.

Harvard

al, H. J. E. 2026, Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network, Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co, Ltd, available at: https://doi.org/10.19753/j.issn1001-1390.2026.03.011 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network
Autore / collaboratori
HE Jianbo et al
Editore
Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd
Anno di pubblicazione
2026
ISSN
1001-1390
ISSN
1001-1390
Lingua
zho

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato