Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly

Maarit Kangas; Raija Korpelainen; Irene Vikman; Lars Nyberg; Timo Jämsä · Gerontology · 2014

Accesso istituzionale disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

OpenAlex OpenAlex Works
Entrar por OpenAlex
Accesso principale

Accesso istituzionale disponibile

El acceso puede requerir institución, suscripción, proxy, VPN o autenticación.
Apri accesso

Riepilogo

Descripción general del contenido del recurso.

BACKGROUND: About a third of home-dwelling older people fall each year, and institutionalized older people even report a two- or threefold higher rate for falling. Automatic fall detection systems have been developed to support the independent and secure living of the elderly. Even though good fall detection sensitivity and specificity in laboratory settings have been reported, knowledge about the sensitivity and specificity of these systems in real-life conditions is still lacking. OBJECTIVE: The aim of this study was to evaluate the long-term fall detection sensitivity and false alarm rate of a fall detection prototype in real-life use. METHODS: A total of 15,500 h of real-life data from 16 older people, including both fallers and nonfallers, were monitored using an accelerometry-based sensor system with an implemented fall detection algorithm. RESULTS: The fall detection system detected 12 out of 15 real-life falls, having a sensitivity of 80.0%, with a false alarm rate of 0.049 alarms per usage hour with the implemented real-time system. With minor modification of data analysis the false alarm rate was reduced to 0.025 false alarms per hour, equating to 1 false fall alarm per 40 usage hours. CONCLUSION: These data suggest that automatic accelerometric fall detection systems might offer a tool for improving safety among older people.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Kangas, M, Korpelainen, R, Vikman, I, Nyberg, L, & Jämsä, T. (2014). Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly. https://doi.org/10.1159/000362720

MLA

Kangas, Maarit, et al. "Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly." 2014. https://doi.org/10.1159/000362720.

Chicago

Kangas, Maarit, Raija Korpelainen, Irene Vikman, Lars Nyberg, and Timo Jämsä. 2014. "Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly.". https://doi.org/10.1159/000362720.

Harvard

Kangas, M. et al. 2014, Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly, Gerontology, available at: https://doi.org/10.1159/000362720 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly
Autore / collaboratori
Maarit Kangas; Raija Korpelainen; Irene Vikman; Lars Nyberg; Timo Jämsä
Editore
Gerontology
Anno di pubblicazione
2014
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato