Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo de revista

THE COMPARISON OF DUAL-ENERGY X-RAY ABSORBTIOMETRY AND BIOELECTRIC IMPEDANCE ANALYSIS IN DETERMINATION OF BODY COMPOSITION IN HEMODIALYSIS PATIENTS

Aykut SİFİL et al · Turkish Society of Nephrology · 2019

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

"ONE HUNDRED AND THIRTY-FIVE HOURS UNDER THE RUIN : A CASE WITH TRAUMATIC RHABDOMYOLYSIS IN GÖLCÜK EARTHQUAKE"

Questa pubblicazione seriale contiene 1.344 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo
Otras opciones de acceso Elegí el proveedor disponible para esta ficha.
DOAJ CSV Export DOAJ - Open Access Journals
Acceder por DOAJ CSV Export
DOAJ OAI-PMH DOAJ Articles
Acceder por DOAJ OAI-PMH

Altre opzioni disponibili

Se la risorsa è presente su più piattaforme, puoi scegliere dove aprirla.

DOAJ CSV Export DOAJ - Open Access Journals Accesso disponibile
Apri
DOAJ OAI-PMH DOAJ Articles Accesso disponibile
Apri

Riepilogo

Descripción general del contenido del recurso.

Chronic renal failure causes changes in body composition. Dual-Energy X-Ray Absorbsiometry (DEXA) and bioelectric impedance analysis (BIA) are the techniques to evaluate body composition in chronic renal failure. In the present study, we aimed to perform comparative analysis of DEXA and BIA in determination of minor changes in body composition occurring during single dialysis session. Each patient was weighed and body composition was measured by DEXA and BIA before and after dialysis. When measurements before and after dialysis by DEXA were considered, changes in fat mass and bone mineral content were not statistically significant, whereas lean body mass and total weight measurements before and after dialysis differed significantly. BIA was considered, fat mass, lean body mass and water content before and after dialysis were found to be statistically significantly different. When results obtained by DEXA BIA were compared differences in means of EM and LBM were not statistically significant and they were found to be positively correlated. As a conclusion; DEXA is a quite sensitive technique in determination of FM, LBM and bone mineral content and can be used in dialysis patients to determine short and long term changes in body composition. Despite BIA is less reliable in determination of body composition, it can be still used in determination of dry weight in conjunction with clinical parameters since it is a noninvasive and easy to perform technique at bedside.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. S. E. (2019). THE COMPARISON OF DUAL-ENERGY X-RAY ABSORBTIOMETRY AND BIOELECTRIC IMPEDANCE ANALYSIS IN DETERMINATION OF BODY COMPOSITION IN HEMODIALYSIS PATIENTS. https://turkjnephrol.org/index.php/pub/article/view/273

MLA

al, Aykut SİFİL et. "THE COMPARISON OF DUAL-ENERGY X-RAY ABSORBTIOMETRY AND BIOELECTRIC IMPEDANCE ANALYSIS IN DETERMINATION OF BODY COMPOSITION IN HEMODIALYSIS PATIENTS." 2019. https://turkjnephrol.org/index.php/pub/article/view/273.

Chicago

al, Aykut SİFİL et. 2019. "THE COMPARISON OF DUAL-ENERGY X-RAY ABSORBTIOMETRY AND BIOELECTRIC IMPEDANCE ANALYSIS IN DETERMINATION OF BODY COMPOSITION IN HEMODIALYSIS PATIENTS.". https://turkjnephrol.org/index.php/pub/article/view/273.

Harvard

al, A. S. E. 2019, THE COMPARISON OF DUAL-ENERGY X-RAY ABSORBTIOMETRY AND BIOELECTRIC IMPEDANCE ANALYSIS IN DETERMINATION OF BODY COMPOSITION IN HEMODIALYSIS PATIENTS, Turkish Society of Nephrology, available at: https://turkjnephrol.org/index.php/pub/article/view/273 [Accessed 10 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
THE COMPARISON OF DUAL-ENERGY X-RAY ABSORBTIOMETRY AND BIOELECTRIC IMPEDANCE ANALYSIS IN DETERMINATION OF BODY COMPOSITION IN HEMODIALYSIS PATIENTS
Autore / collaboratori
Aykut SİFİL et al
Editore
Turkish Society of Nephrology
Anno di pubblicazione
2019
ISSN
2667-4440
ISSN
2667-4440
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato