← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria

Mmatlou D. Seema et al · AOSIS · 2026

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

Background: The rising demand for interventional radiology procedures (IRPs) performed under fluoroscopic guidance increases the risk of harmful radiation effects for patients and staff. Radiation dose optimisation using diagnostic reference levels (DRLs) is necessary to keep radiation ‘as low as reasonably achievable (ALARA)’. Establishment of DRLs is required for radiation imaging centres; however, only a few have published them in South Africa. This study aimed to establish local diagnostic reference levels (LDRLs) for IRPs and compare them with DRLs of local and international imaging centres. Methods: A retrospective descriptive study was conducted at a single imaging centre. The IRPs performed on adults between 01 January 2023 and 31 December 2023 were considered. Ethical clearance was obtained before data collection. Data on fluoroscopy time (FT) and kerma air product (KAP) were obtained from a procedure register book. The third quartile (75th percentile) of the dataset for KAP and FT of every IRP indicated the LDRLs. Results: A total of 375 IRPs were analysed. The most frequently performed IRP was cerebral interventions (21%, n = 80). Aortic interventions recorded the highest dose LDRL (KAP = 252.5 Gy/cm2), followed by cerebral interventions (KAP = 211.3 Gy/cm2). Cerebral interventions recorded the longest FT (56.8 min), followed by aortic interventions (36.2 min), both of which exceeded the local centres’ DRL ranges. Permanent catheterisation (KAP = 10.7 Gy/cm2) also exceeded the international DRL range. Conclusion: Established LDRLs for IRPs were mostly within local and international DRL ranges. Contribution: The study contributed to the establishment of local, national and regional DRLs, which assisted imaging centres in optimising radiation doses for IRPs.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. D. S. E. (2026). Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria. https://doi.org/10.4102/jcmsa.v4i1.279

MLA

al, Mmatlou D. Seema et. "Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria." 2026. https://doi.org/10.4102/jcmsa.v4i1.279.

Chicago

al, Mmatlou D. Seema et. 2026. "Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria.". https://doi.org/10.4102/jcmsa.v4i1.279.

Harvard

al, M. D. S. E. 2026, Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria, AOSIS, available at: https://doi.org/10.4102/jcmsa.v4i1.279 [Accessed 28 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria
Autor / colaboradores
Mmatlou D. Seema et al
Editorial
AOSIS
Año de publicación
2026
ISSN
3105-4331
ISSN
3105-4331
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado