Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Macular hole surgical outcomes at a retinal centre in Johannesburg, South Africa

Ting-Ying M. Liu et al · AOSIS · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Background: A full-thickness macular hole (FTMH) causes central vision loss. Although modern vitrectomy techniques achieve high closure rates, functional recovery remained variable. Aim: This study aimed to describe the surgical outcomes of FTMH repair in patients treated at a retinal centre in South Africa. Setting: The study was conducted at a predominantly retinal private-sector centre in Johannesburg, South Africa. Methods: This retrospective case series evaluated anatomical and visual outcomes of patients who underwent FTMH repair at Northcliff Eye Centre over 10 years. Results: The study included 157 eyes. The median patient age was 67 years, and 72% were female. The median FTMH size was 422 µm, with 54% classified as large according to the International Vitreomacular Traction Study (IVTS) classification. Anatomical closure was achieved in 90% at 1 month and 98.7% at 3 months. The median visual acuity improved from 0.7 Logarithm of the Minimum Angle of Resolution (logMAR) to 0.22 logMAR at 3 months, a gain of 24 letters (P 0.001). Smaller holes and U-shaped closure morphology were associated with superior outcomes. Complications were minimal, with no retinal detachments reported. Conclusion: Vitrectomy with internal limiting membrane (ILM) peeling achieved high closure rates, with smaller holes and U-shaped closures predicting superior visual outcomes, underscoring the value of early intervention and optical coherence tomography-based prognostication. Contribution: This study provided region-specific outcome data to support surgical decision-making and patient counselling in sub-Saharan Africa.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, T. Y. M. L. E. (2026). Macular hole surgical outcomes at a retinal centre in Johannesburg, South Africa. https://doi.org/10.4102/aveh.v85i1.1125

MLA

al, Ting-Ying M. Liu et. "Macular hole surgical outcomes at a retinal centre in Johannesburg, South Africa." 2026. https://doi.org/10.4102/aveh.v85i1.1125.

Chicago

al, Ting-Ying M. Liu et. 2026. "Macular hole surgical outcomes at a retinal centre in Johannesburg, South Africa.". https://doi.org/10.4102/aveh.v85i1.1125.

Harvard

al, T. Y. M. L. E. 2026, Macular hole surgical outcomes at a retinal centre in Johannesburg, South Africa, AOSIS, available at: https://doi.org/10.4102/aveh.v85i1.1125 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Macular hole surgical outcomes at a retinal centre in Johannesburg, South Africa
Autore / collaboratori
Ting-Ying M. Liu et al
Editore
AOSIS
Anno di pubblicazione
2026
ISSN
2413-3183
ISSN
2413-3183
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato