Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo de revista

Correlation between pixel value of CBCT and Hounsfield Unit of MDCT on teeth and mandible cortical bone

A. Azhari et al · faculty of dentistry universitas gadjah mada · 2018

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A Comparative microleakage analysis of two bioactive root perforation sealing materials

Questa pubblicazione seriale contiene 501 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Cone-beam computed tomography (CBCT) is an imaging modality widely used in dentistry over multi detector computed tomography (MDCT). It is in view of its high resolution with relatively lower dose. MDCT is able to show Hounsfield Unit (HU) which is proportional to x-ray attenuation degree by the tissue. The x-ray attenuation degree in CBCT is shown in grayscale value with pixel values unit. The aim of this study was to determine the correlation of pixel values in CBCT with HU in MDCT. We used secondary data from RSGM Universitas Padjajaran patient who had CBCT and MDCT. Measurement was done on the cortical areas (lingual, buccal, and posterior side) of the mandible and teeth 47 (email, dentin, and pulp) with 5 regions of interest (ROIs) on each area. DICOM software was used for the measurement on CBCT and MDCT data. The result indicated a strong correlation between pixel value in CBCT and HU in MDCT on the cortical bone and teeth area (R=0.846). Linear regression resulted in an equation to derive HU value from pixel value of cortical bone and teeth area, which is y = 1,9011x + 177,15. The conclusion is HU can be derived from CBCT by converting with regression equation.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. A. E. (2018). Correlation between pixel value of CBCT and Hounsfield Unit of MDCT on teeth and mandible cortical bone. https://doi.org/10.22146/majkedgiind.26808

MLA

al, A. Azhari et. "Correlation between pixel value of CBCT and Hounsfield Unit of MDCT on teeth and mandible cortical bone." 2018. https://doi.org/10.22146/majkedgiind.26808.

Chicago

al, A. Azhari et. 2018. "Correlation between pixel value of CBCT and Hounsfield Unit of MDCT on teeth and mandible cortical bone.". https://doi.org/10.22146/majkedgiind.26808.

Harvard

al, A. A. E. 2018, Correlation between pixel value of CBCT and Hounsfield Unit of MDCT on teeth and mandible cortical bone, faculty of dentistry universitas gadjah mada, available at: https://doi.org/10.22146/majkedgiind.26808 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Correlation between pixel value of CBCT and Hounsfield Unit of MDCT on teeth and mandible cortical bone
Autore / collaboratori
A. Azhari et al
Editore
faculty of dentistry universitas gadjah mada
Anno di pubblicazione
2018
ISSN
2460-0164
ISSN
2460-0164
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato