← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Document

Artificial pancreas: clinical study in Latin America without premeal insulin boluses

Sánchez-Peña, Ricardo et al · RI ITBA · 2019

Acceso abierto al texto completo
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Acceso abierto al texto completo

Texto completo identificado como acceso abierto.
Abrir texto

Resumen

Descripción general del contenido del recurso.

"Background: Emerging therapies such as closed-loop (CL) glucose control, also known as artificial pancreas (AP) systems, have shown significant improvement in type 1 diabetes mellitus (T1DM) management. However, demanding patient intervention is still required, particularly at meal times. To reduce treatment burden, the automatic regulation of glucose (ARG) algorithm mitigates postprandial glucose excursions without feedforward insulin boluses. This work assesses feasibility of this new strategy in a clinical trial. Methods: A 36-hour pilot study was performed on five T1DM subjects to validate the ARG algorithm. Subjects wore a subcutaneous continuous glucose monitor (CGM) and an insulin pump. Insulin delivery was solely commanded by the ARG algorithm, without premeal insulin boluses. This was the first clinical trial in Latin America to validate an AP controller. Results: For the total 36-hour period, results were as follows: average time of CGM readings in range 70-250 mg/dl: 88.6%, in range 70-180 mg/dl: 74.7%, <70 mg/dl: 5.8%, and <50 mg/dl: 0.8%. Results improved analyzing the final 15-hour period of this trial. In that case, the time spent in range was 70-250 mg/dl: 94.7%, in range 70-180 mg/dl: 82.6%, <70 mg/dl: 4.1%, and <50 mg/dl: 0.2%. During the last night the time spent in range was 70-250 mg/dl: 95%, in range 70-180 mg/dl: 87.7%, <70 mg/dl: 5.0%, and <50 mg/dl: 0.0%. No severe hypoglycemia occurred. No serious adverse events were reported. Conclusions: The ARG algorithm was successfully validated in a pilot clinical trial, encouraging further tests with a larger number of patients and in outpatient settings."

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Sánchez-Peña, R. E. A. (2019). Artificial pancreas: clinical study in Latin America without premeal insulin boluses. RI ITBA. http://ri.itba.edu.ar/handle/20.500.14769/1653

MLA

Sánchez-Peña, Ricardo et al. Artificial pancreas: clinical study in Latin America without premeal insulin boluses. RI ITBA, 2019. http://ri.itba.edu.ar/handle/20.500.14769/1653.

Chicago

Sánchez-Peña, Ricardo et al. 2019. Artificial pancreas: clinical study in Latin America without premeal insulin boluses. RI ITBA. http://ri.itba.edu.ar/handle/20.500.14769/1653.

Harvard

Sánchez-Peña, R. E. A. 2019, Artificial pancreas: clinical study in Latin America without premeal insulin boluses, RI ITBA, available at: http://ri.itba.edu.ar/handle/20.500.14769/1653 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Artificial pancreas: clinical study in Latin America without premeal insulin boluses
Autor / colaboradores
Sánchez-Peña, Ricardo et al
Editorial
RI ITBA
Año de publicación
2019
ISSN
1932-2968
ISSN
1932-2968
Idioma
en

Materias

Explorá otros recursos relacionados a partir de estas materias.