Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Document

Artificial pancreas: clinical study in Latin America without premeal insulin boluses

Sánchez-Peña, Ricardo et al · RI ITBA · 2019

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

RI ITBA RI ITBA OAI-PMH
Entrar por RI ITBA
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo
Otras opciones de acceso Elegí el proveedor disponible para esta ficha.
RI ITBA OAI-PMH
Acceder por RI ITBA OAI-PMH

Riepilogo

Descripción general del contenido del recurso.

"Background: Emerging therapies such as closed-loop (CL) glucose control, also known as artificial pancreas (AP) systems, have shown significant improvement in type 1 diabetes mellitus (T1DM) management. However, demanding patient intervention is still required, particularly at meal times. To reduce treatment burden, the automatic regulation of glucose (ARG) algorithm mitigates postprandial glucose excursions without feedforward insulin boluses. This work assesses feasibility of this new strategy in a clinical trial. Methods: A 36-hour pilot study was performed on five T1DM subjects to validate the ARG algorithm. Subjects wore a subcutaneous continuous glucose monitor (CGM) and an insulin pump. Insulin delivery was solely commanded by the ARG algorithm, without premeal insulin boluses. This was the first clinical trial in Latin America to validate an AP controller. Results: For the total 36-hour period, results were as follows: average time of CGM readings in range 70-250 mg/dl: 88.6%, in range 70-180 mg/dl: 74.7%, <70 mg/dl: 5.8%, and <50 mg/dl: 0.8%. Results improved analyzing the final 15-hour period of this trial. In that case, the time spent in range was 70-250 mg/dl: 94.7%, in range 70-180 mg/dl: 82.6%, <70 mg/dl: 4.1%, and <50 mg/dl: 0.2%. During the last night the time spent in range was 70-250 mg/dl: 95%, in range 70-180 mg/dl: 87.7%, <70 mg/dl: 5.0%, and <50 mg/dl: 0.0%. No severe hypoglycemia occurred. No serious adverse events were reported. Conclusions: The ARG algorithm was successfully validated in a pilot clinical trial, encouraging further tests with a larger number of patients and in outpatient settings."

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Sánchez-Peña, R. E. A. (2019). Artificial pancreas: clinical study in Latin America without premeal insulin boluses. RI ITBA. http://ri.itba.edu.ar/handle/20.500.14769/1653

MLA

Sánchez-Peña, Ricardo et al. Artificial pancreas: clinical study in Latin America without premeal insulin boluses. RI ITBA, 2019. http://ri.itba.edu.ar/handle/20.500.14769/1653.

Chicago

Sánchez-Peña, Ricardo et al. 2019. Artificial pancreas: clinical study in Latin America without premeal insulin boluses. RI ITBA. http://ri.itba.edu.ar/handle/20.500.14769/1653.

Harvard

Sánchez-Peña, R. E. A. 2019, Artificial pancreas: clinical study in Latin America without premeal insulin boluses, RI ITBA, available at: http://ri.itba.edu.ar/handle/20.500.14769/1653 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Artificial pancreas: clinical study in Latin America without premeal insulin boluses
Autore / collaboratori
Sánchez-Peña, Ricardo et al
Editore
RI ITBA
Anno di pubblicazione
2019
ISSN
1932-2968
ISSN
1932-2968
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato