Third-order nonlinear sliding-mode controller for improving the performance of a grid-connected PV system

Noureddine Ech-cherki et al · KeAi Communications Co., Ltd · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

The performance of Photovoltaic (PV) power generation systems, using traditional Vector Current Controllers based on Proportional–Integral Action (CVC-PI), exhibits marked non-linearity and is strongly influenced by meteorological variations. Due to its robustness in the face of these challenges, Sliding Mode Control (SMC) has been widely used in this field, but SMC has certain inconveniences, notably the phenomenon of chattering and ripples in active (P) and reactive (Q) power. These limitations remain partially unresolved, even with the use of Second-order SMC (SMC-2). To address these limitations, this work proposes a robust, non-linear control based on the Third-order SMC in Dual Mode conversion (DM-SMC-3). To demonstrate the effectiveness of the proposed DM-SMC-3 control, a comparative study was carried out between DM-SMC-3, SMC-2, SMC and CVC-PI in terms of chattering reduction, dynamic response time, overshoot, P and Q power ripples and the Total Harmonic Distortion (THD) of the current injected into the electrical grid. The DM-SMC-3 is also used to guarantee Maximum Power Point Tracking (MPPT). The system is designed and simulated using Matlab/Simulink software. The simulation results demonstrated the significant contribution of the DM-SMC-3, with a 99% reduction in overshoot compared to other controllers. THD was reduced to 0.58%. The average reference tracking efficiency was 99.68%, and 99.41% under the temperature and irradiation conditions used. What is more, the DM-SMC-3 takes just 35ms to reach the Maximum Power Point (MPP). It also reduced P and Q power ripples, demonstrating the robustness of the proposed controller in the face of chattering.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, N. E. C. E. (2026). Third-order nonlinear sliding-mode controller for improving the performance of a grid-connected PV system. https://doi.org/10.1016/j.grets.2025.100280

MLA

al, Noureddine Ech-cherki et. "Third-order nonlinear sliding-mode controller for improving the performance of a grid-connected PV system." 2026. https://doi.org/10.1016/j.grets.2025.100280.

Chicago

al, Noureddine Ech-cherki et. 2026. "Third-order nonlinear sliding-mode controller for improving the performance of a grid-connected PV system.". https://doi.org/10.1016/j.grets.2025.100280.

Harvard

al, N. E. C. E. 2026, Third-order nonlinear sliding-mode controller for improving the performance of a grid-connected PV system, KeAi Communications Co, Ltd, available at: https://doi.org/10.1016/j.grets.2025.100280 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Third-order nonlinear sliding-mode controller for improving the performance of a grid-connected PV system
Autore / collaboratori
Noureddine Ech-cherki et al
Editore
KeAi Communications Co., Ltd
Anno di pubblicazione
2026
ISSN
2949-7361
ISSN
2949-7361
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato