← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Efficacy Comparison of Open Reduction and Robot‐Aided Infra‐Acetabular and Posterior Column Screws Fixation in Complex Acetabular Fractures Surgery: Union Plate Versus Reconstruction Plate

Jianan Chen et al · Wiley · 2026

Acceso abierto disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Acceso abierto disponible

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Abrir recurso

Resumen

Descripción general del contenido del recurso.

ABSTRACT Background An anatomical supra‐pectineal quadrilateral surface buttress plate (Union Plate) has been designed and shown promising mechanical strength in vivo. Robot‐aided technique has shown promising results in navigation of infra‐acetabular and posterior column screws placement. This study sought to further examine whether the emerging anatomical plate provided advantages over the reconstruction plate in robot‐aided complex acetabular fracture surgery. Methods A retrospective cohort analysis comparing two internal fixation methods was conducted between September 2023 and January 2025. Specifically, 23 patients with complex acetabular fractures received robot‐aided Union Plate fixation (Union Plate group), while another 20 patients underwent robot‐aided reconstruction plate fixation (Reconstruction plate group). Intra‐operative plate contouring time, robot‐aided manipulation time, the number of channel adjustments per periarticular long screws, total operation time, blood loss, periarticular long screw placement quality, fracture reduction quality, hip joint function, and postoperative complications were compared between the two groups. Results With identical robotic assistance, the Union Plate group experienced significantly shorter times for robot‐aided manipulation (−12 min), intraoperative plate contouring (−9 min), and total operation (−23 min), along with reduced blood loss (−128 mL) and fewer channel adjustments of the periarticular long screws, compared to the reconstruction plate group. Both groups achieved satisfactory periarticular long screws placement, with a 95.7% perfect rate in the Union Plate group and 90.4% in the reconstruction plate group, showing no significant difference. Neither group experienced iatrogenic neurovascular injuries or screw penetration. There were also no significant differences in postoperative complications, fracture reduction quality, or hip joint function between the groups. Conclusion In surgery for complex acetabular fractures, the Union Plate showed superior operability and safety compared to traditional reconstruction plates. It required less time for robot manipulation, intraoperative plate contouring, and total operation, while also resulting in reduced blood loss and fewer adjustments of the periarticular long screws.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. C. E. (2026). Efficacy Comparison of Open Reduction and Robot‐Aided Infra‐Acetabular and Posterior Column Screws Fixation in Complex Acetabular Fractures Surgery: Union Plate Versus Reconstruction Plate. https://doi.org/10.1111/os.70312

MLA

al, Jianan Chen et. "Efficacy Comparison of Open Reduction and Robot‐Aided Infra‐Acetabular and Posterior Column Screws Fixation in Complex Acetabular Fractures Surgery: Union Plate Versus Reconstruction Plate." 2026. https://doi.org/10.1111/os.70312.

Chicago

al, Jianan Chen et. 2026. "Efficacy Comparison of Open Reduction and Robot‐Aided Infra‐Acetabular and Posterior Column Screws Fixation in Complex Acetabular Fractures Surgery: Union Plate Versus Reconstruction Plate.". https://doi.org/10.1111/os.70312.

Harvard

al, J. C. E. 2026, Efficacy Comparison of Open Reduction and Robot‐Aided Infra‐Acetabular and Posterior Column Screws Fixation in Complex Acetabular Fractures Surgery: Union Plate Versus Reconstruction Plate, Wiley, available at: https://doi.org/10.1111/os.70312 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Efficacy Comparison of Open Reduction and Robot‐Aided Infra‐Acetabular and Posterior Column Screws Fixation in Complex Acetabular Fractures Surgery: Union Plate Versus Reconstruction Plate
Autor / colaboradores
Jianan Chen et al
Editorial
Wiley
Año de publicación
2026
ISSN
1757-7853
ISSN
1757-7853
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado