← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Application of a Novel Surgical Instrumentation System for Subtrochanteric Shortening Osteotomy in Total Hip Arthroplasty: A Cohort Study

Zheng Cao et al · Wiley · 2026

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

ABSTRACT Objective Subtrochanteric shortening osteotomy (SSO) with autogenous cortical plate grafting is a critical but technically demanding procedure in total hip arthroplasty for Crowe type IV developmental dysplasia of the hip. Conventional instruments often result in inaccurate osteotomies and unstable graft fixation. This study aimed to evaluate a novel surgical instrumentation system designed to address these challenges. Methods A retrospective cohort study was conducted on 49 patients (60 hips) with Crowe type IV DDH who underwent primary THA with SSO. The control group included 25 patients (30 hips) treated with conventional instruments. The novel instrumentation group included 24 patients (30 hips) treated with the newly developed system. All surgeries were performed by a single senior surgeon. Demographic and clinical data were analyzed, and all patients completed the 24‐month postoperative follow‐up. Statistical analysis was performed using t‐tests and chi‐squared tests as appropriate. Results The mean operative time was significantly shorter in the novel instrumentation group than in the control group (t = 2.123, p = 0.040). The novel instrumentation system was estimated to reduce the time required for the autogenous cortical plate technique by 43%. Patients in the novel instrumentation group also reported significantly less intraoperative blood loss (t = 3.078, p = 0.003). The satisfaction rate regarding autogenous graft and wire positions was significantly higher in the novel instrumentation group (χ 2 = 5.455, p = 0.020). No significant differences were observed in clinical scores between the two groups during the 24‐month follow‐up. No severe perioperative or postoperative complications occurred in either group. Conclusion The novel surgical instrumentation system demonstrated advantages over conventional devices in terms of operating time, blood loss, and satisfaction with autogenous graft and wire positioning. It represents an ideal set of surgical tools for Crowe type IV DDH patients undergoing THA with SSO. Level of Evidence Level III, retrospective study.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Z. C. E. (2026). Application of a Novel Surgical Instrumentation System for Subtrochanteric Shortening Osteotomy in Total Hip Arthroplasty: A Cohort Study. https://doi.org/10.1111/os.70302

MLA

al, Zheng Cao et. "Application of a Novel Surgical Instrumentation System for Subtrochanteric Shortening Osteotomy in Total Hip Arthroplasty: A Cohort Study." 2026. https://doi.org/10.1111/os.70302.

Chicago

al, Zheng Cao et. 2026. "Application of a Novel Surgical Instrumentation System for Subtrochanteric Shortening Osteotomy in Total Hip Arthroplasty: A Cohort Study.". https://doi.org/10.1111/os.70302.

Harvard

al, Z. C. E. 2026, Application of a Novel Surgical Instrumentation System for Subtrochanteric Shortening Osteotomy in Total Hip Arthroplasty: A Cohort Study, Wiley, available at: https://doi.org/10.1111/os.70302 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Application of a Novel Surgical Instrumentation System for Subtrochanteric Shortening Osteotomy in Total Hip Arthroplasty: A Cohort Study
Autor / colaboradores
Zheng Cao et al
Editorial
Wiley
Año de publicación
2026
ISSN
1757-7853
ISSN
1757-7853
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado