Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Diagnostic Accuracy of Wearable ECG Devices for Atrial Fibrillation and ST-Segment Changes: A Systematic Review

Mara Sînziana Sîngeap et al · MDPI AG · 2025

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

<b>Background</b>: Wearable electrocardiography (ECG) devices such as smartwatches offer a novel means for detecting cardiac arrhythmias, particularly atrial fibrillation (AF), and ST-segment abnormalities. Their role in complementing or replacing traditional ECG methods is being increasingly investigated. <b>Objective</b>: To evaluate the diagnostic performance (sensitivity, specificity) of wearable ECG devices in detecting AF and ST-segment changes, compared to 12-lead ECG as the gold standard. <b>Methods</b>: A systematic search was performed in PubMed, Scopus, and additionally, the SpringerLink platform was consulted up to June 2025, targeting open-access, English-language clinical studies from the last five years. Inclusion criteria: adult population, use of a wearable ECG device, 12-lead ECG comparator, and diagnostic accuracy reporting. Out of 145 records, 5 studies met the inclusion criteria. The systematic review protocol was not prospectively registered in PROSPERO due to the limited number of available studies and the exploratory nature of the topic, which focused on the most recent clinical evaluations of wearable ECG devices. However, the review strictly adhered to the PRISMA 2020 guidelines for systematic reviews to ensure methodological transparency and reproducibility. <b>Results</b>: Five studies encompassing a total of 1133 participants were incorporated into the analysis. Devices evaluated included Apple Watch (Series 4–6), KardiaMobile 6L, FibriCheck, Preventicus, and HUAMI dynamic ECG. Sensitivity ranged from 83% to 100%, and specificity from 79% to 100%. Algorithm improvements and repeated measurements significantly reduced inconclusive recordings. Multichannel ECG methods using smartwatches showed high agreement with 12-lead ECG in ST-elevation myocardial infarction detection. <b>Conclusions</b>: Wearable ECG devices demonstrate high diagnostic performance for AF and ST-segment abnormalities, especially in supervised environments. However, inconclusive recordings and algorithm limitations remain barriers to widespread clinical use. Real-world validation and algorithm refinement are needed for broader adoption.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. S. S. E. (2025). Diagnostic Accuracy of Wearable ECG Devices for Atrial Fibrillation and ST-Segment Changes: A Systematic Review. https://doi.org/10.3390/diagnostics15243162

MLA

al, Mara Sînziana Sîngeap et. "Diagnostic Accuracy of Wearable ECG Devices for Atrial Fibrillation and ST-Segment Changes: A Systematic Review." 2025. https://doi.org/10.3390/diagnostics15243162.

Chicago

al, Mara Sînziana Sîngeap et. 2025. "Diagnostic Accuracy of Wearable ECG Devices for Atrial Fibrillation and ST-Segment Changes: A Systematic Review.". https://doi.org/10.3390/diagnostics15243162.

Harvard

al, M. S. S. E. 2025, Diagnostic Accuracy of Wearable ECG Devices for Atrial Fibrillation and ST-Segment Changes: A Systematic Review, MDPI AG, available at: https://doi.org/10.3390/diagnostics15243162 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Diagnostic Accuracy of Wearable ECG Devices for Atrial Fibrillation and ST-Segment Changes: A Systematic Review
Autore / collaboratori
Mara Sînziana Sîngeap et al
Editore
MDPI AG
Anno di pubblicazione
2025
ISSN
2075-4418
ISSN
2075-4418
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato