Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Data-Oriented Parallel-in-Time Electromagnetic Transient Simulation of AC–DC Grid

Yang Li et al · IEEE · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

An electromagnetic transient (EMT) simulation framework is developed by integrating the Parallel-in-Time algorithm with a data-oriented Entity&#x2013;Component&#x2013;System (ECS) architecture. The proposed method aims to enhance computational efficiency for EMT problems by jointly exploiting temporal concurrency and memory locality on multi-core CPU platforms. The ECS paradigm reorganizes component data into cache-friendly, structure-of-arrays layouts, reducing memory access latency and enabling efficient multithreaded execution. On top of this, the Parareal algorithm introduces time-parallelism by decomposing the simulation horizon into macro segments for concurrent fine-grid integration and coarse&#x2013;fine correction iterations. A delay-consistent segmentation strategy is introduced to accommodate traveling-wave transmission-line effects without sacrificing parallel scalability or numerical accuracy. The framework is implemented in Rust based on the Bevy engine and evaluated using a modified IEEE 118-bus AC-DC network. Numerical validation confirms agreement with PSCAD/EMTDC<sup>&#x00AE;</sup> reference waveforms under diverse scenarios, including synchronous generator ramp-up, three-phase fault switching, line energization, and MMC DC-link dynamics. Performance benchmarks reveal that optimal integration parameter tuning can yield significant speedups: a maximum runtime reduction of 44.1% is achieved at <inline-formula> <tex-math notation="LaTeX">$\delta {t}$ </tex-math></inline-formula> = <inline-formula> <tex-math notation="LaTeX">${5}~\mu $ </tex-math></inline-formula>s with <inline-formula> <tex-math notation="LaTeX">$\Delta {t}$ </tex-math></inline-formula> = <inline-formula> <tex-math notation="LaTeX">${80}~\mu $ </tex-math></inline-formula>s, while a 38.5% gain is recorded at <inline-formula> <tex-math notation="LaTeX">$\delta {t}$ </tex-math></inline-formula> = <inline-formula> <tex-math notation="LaTeX">${1}~\mu $ </tex-math></inline-formula>s with <inline-formula> <tex-math notation="LaTeX">$\Delta {t}$ </tex-math></inline-formula> = <inline-formula> <tex-math notation="LaTeX">${25}~\mu $ </tex-math></inline-formula>s, where <inline-formula> <tex-math notation="LaTeX">$\delta {t}$ </tex-math></inline-formula> and <inline-formula> <tex-math notation="LaTeX">$\Delta {t}$ </tex-math></inline-formula> denote the fine and coarse time-step in the parallel-in-time framework. These results highlight the practical advantages of combining time-parallel algorithms with data-oriented simulation structures for accelerating EMT simulations under realistic grid conditions.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Y. L. E. (2026). Data-Oriented Parallel-in-Time Electromagnetic Transient Simulation of AC–DC Grid. https://doi.org/10.1109/OAJPE.2026.3684873

MLA

al, Yang Li et. "Data-Oriented Parallel-in-Time Electromagnetic Transient Simulation of AC–DC Grid." 2026. https://doi.org/10.1109/OAJPE.2026.3684873.

Chicago

al, Yang Li et. 2026. "Data-Oriented Parallel-in-Time Electromagnetic Transient Simulation of AC–DC Grid.". https://doi.org/10.1109/OAJPE.2026.3684873.

Harvard

al, Y. L. E. 2026, Data-Oriented Parallel-in-Time Electromagnetic Transient Simulation of AC–DC Grid, IEEE, available at: https://doi.org/10.1109/OAJPE.2026.3684873 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Data-Oriented Parallel-in-Time Electromagnetic Transient Simulation of AC–DC Grid
Autore / collaboratori
Yang Li et al
Editore
IEEE
Anno di pubblicazione
2026
ISSN
2687-7910
ISSN
2687-7910
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato