Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty: a prospective randomized controlled trial

Florian Kruse et al · The British Editorial Society of Bone & Joint Surgery · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Aims: Cementless femoral fixation is widely used in total hip arthroplasty (THA), with increasing interest in shorter femoral component designs. These femoral components aim to preserve proximal bone, promote physiological load transfer, and facilitate minimally invasive approaches. Among these, ‘shortened’ femoral components, derived from conventional stems and retaining a diaphyseal extension, may offer advantages in terms of implant positioning. However, clinical evidence regarding their mechanical reliability remains limited. This study aimed to compare the two-year radiological stability of a shortened uncemented quadrangular femoral component with that of its conventional-length counterpart in patients undergoing THA for osteoarthritis. Methods: We conducted a prospective, single-blind, randomized, noninferiority trial between January 2018 and December 2021. Patients undergoing primary THA were randomly assigned to receive either the conventional-length quadrangular femoral component or its shortened version. The primary outcome was femoral component migration at two years, assessed with Ein Bild Roentgen analyze - femoral component analysis (EBRA-FCA). Secondary outcomes included intraoperative and postoperative complication rates, as well as the 12-item Oxford Hip Score (OHS) at 12 months. Results: A total of 143 hips were randomized, with 139 (70 conventional-length, 69 shortened) included in the clinical analysis. Per-protocol radiological analysis was carried out on 98 hips (49 hips per group). At two years, mean femoral component migration was 0.94 mm (SD 0.49) in the shortened-femoral component group and 0.86 mm (SD 0.52) in the conventional-length group. The upper bound of the 90% CI (–0.09 to 0.25) was below the prespecified noninferiority margin of 1 mm. No significant differences were observed in complication rates or functional outcomes (p > 0.05). Conclusion: At two years, radiological outcomes of the shortened quadrangular femoral component were consistent with noninferiority compared with the conventional-length version. Although the planned sample size was not fully reached, the findings remained within the prespecified noninferiority margin. Cite this article: Bone Jt Open 2026;7(4):465–472.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, F. K. E. (2026). Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty: a prospective randomized controlled trial. https://doi.org/10.1302/2633-1462.74.BJO-2026-0006.R1

MLA

al, Florian Kruse et. "Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty: a prospective randomized controlled trial." 2026. https://doi.org/10.1302/2633-1462.74.BJO-2026-0006.R1.

Chicago

al, Florian Kruse et. 2026. "Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty: a prospective randomized controlled trial.". https://doi.org/10.1302/2633-1462.74.BJO-2026-0006.R1.

Harvard

al, F. K. E. 2026, Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty: a prospective randomized controlled trial, The British Editorial Society of Bone & Joint Surgery, available at: https://doi.org/10.1302/2633-1462.74.BJO-2026-0006.R1 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty: a prospective randomized controlled trial
Autore / collaboratori
Florian Kruse et al
Editore
The British Editorial Society of Bone & Joint Surgery
Anno di pubblicazione
2026
ISSN
2633-1462
ISSN
2633-1462
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato