Closing the loop on tourniquet safety in distal radius fracture fixation surgery: a two-cycle quality improvement project

Chloe Lawrence et al · BMJ Publishing Group · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Background The application of intraoperative tourniquets is a fundamental component of distal radius fracture surgery, yet it carries a risk of significant complications. The British Orthopaedic Association (BOA) has published safety guidelines (BOA Standards for Trauma (BOAST)) to standardise practice, but adherence is often suboptimal. This quality improvement project aimed to evaluate and improve compliance with these guidelines in a real-world clinical setting.Methods A two-cycle retrospective audit was conducted at a major trauma centre in the UK. The first cycle (January to April 2023, n=34) established baseline compliance with seven key BOAST documentation standards. Following this, a multifaceted intervention was implemented, including staff education, the introduction of a standardised checklist and the placement of visual reminders in operating theatres. A re-audit was then conducted (May to June 2024, n=63) to measure the impact of these interventions.Results Baseline documentation compliance was extremely low, with only tourniquet pressure recorded in 20.5% (7/34) and tourniquet time documented in 55.9% (19/34). Following the interventions, documentation of tourniquet pressure increased to 59.0% (37/63) and tourniquet site, padding, compressive exsanguination, skin condition, tourniquet size and tourniquet time showed modest improvements. Overall compliance, however, remained below optimal levels.Conclusions A targeted quality improvement initiative combining education and practical tools can lead to meaningful improvements in adherence to tourniquet safety guidelines. Despite these gains, persistent documentation gaps highlight the need for more robust, system-level solutions, such as integration into electronic health records, to ensure sustained compliance and enhance patient safety.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. L. E. (2026). Closing the loop on tourniquet safety in distal radius fracture fixation surgery: a two-cycle quality improvement project. https://doi.org/10.1136/bmjoq-2025-003956

MLA

al, Chloe Lawrence et. "Closing the loop on tourniquet safety in distal radius fracture fixation surgery: a two-cycle quality improvement project." 2026. https://doi.org/10.1136/bmjoq-2025-003956.

Chicago

al, Chloe Lawrence et. 2026. "Closing the loop on tourniquet safety in distal radius fracture fixation surgery: a two-cycle quality improvement project.". https://doi.org/10.1136/bmjoq-2025-003956.

Harvard

al, C. L. E. 2026, Closing the loop on tourniquet safety in distal radius fracture fixation surgery: a two-cycle quality improvement project, BMJ Publishing Group, available at: https://doi.org/10.1136/bmjoq-2025-003956 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Closing the loop on tourniquet safety in distal radius fracture fixation surgery: a two-cycle quality improvement project
Autore / collaboratori
Chloe Lawrence et al
Editore
BMJ Publishing Group
Anno di pubblicazione
2026
ISSN
2399-6641
ISSN
2399-6641
Lingua
Inglés
Copiato