Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Impact of HPLC Parameters on Chiral Separation of Nornicotine Enantiomers

Ashraf-Khorassani Mehdi et al · Sciendo · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Given the well-documented pharmacological differences between nicotine and nornicotine enantiomers, understanding their distribution is essential. This knowledge also helps authenticate the enantiomers’ source (natural or synthetic). To improve the quantitative determination methods for these distributions, the influence of additives, modifiers, and sample matrices on the chiral HPLC separation of the nornicotine enantiomers using UV detection is discussed. Changes on the order of 5–10% in selected alcohols as modifiers and selected amines (0.1% changes) as additives were found to have significant effect on the resolution and retention times of nornicotine enantiomers, while sample matrices demonstrated an impact on nornicotine enantiomer resolution (R). Systematic variation in the concentration of ethanol and isopropanol, as modifiers, along with variations in the concentration of diethylamine, triethylamine, and isopropylamine, as additives, revealed that the resolution (R) of the nornicotine enantiomers could be adjusted to values much greater than 2, using mobile phase flow rates of 0.8 and 1 mL/min. The retention times of the nornicotine enantiomer pairs could be varied between ~8 and 20 min, through modification of the mobile phase with the additives and modifiers. As expected, faster mobile phase flow rates of 1 mL/min moderately reduced retention times when compared with influences on retention time caused by changes in the amounts of modifier and additive, with an accompanying slight decrease in the R values. The %RSD values for both nornicotine resolution and retention times consistently remained below 3%. The detection limits for the nornicotine enantiomers were approximately 1 ng on column for each enantiomer. With the judiciously selected optimization of the levels of the hexane mobile phase additive, diethylamine, and modifier, ethanol, coupled with results from previously published results on nicotine and nornicotine alkaloid enantiomer separations, a simultaneous separation of both nornicotine and nicotine enantiomers having R values greater than 2 and an overall retention time of less than 15 min was attained. Noticeable influences on nornicotine enantiomer resolution and co-elution of tobacco extract components with nornicotine enantiomers as a function of mobile phase composition were illustrated and discussed. Previous published results in combination with this current body of work culminate in a well-rounded understanding of the influences of modifier and additive structure and concentration on the resolution as well as a simultaneous separation of nicotine and nornicotine enantiomers employing high performance liquid chromatography.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. K. M. E. (2026). Impact of HPLC Parameters on Chiral Separation of Nornicotine Enantiomers. https://doi.org/10.2478/cttr-2026-0002

MLA

al, Ashraf-Khorassani Mehdi et. "Impact of HPLC Parameters on Chiral Separation of Nornicotine Enantiomers." 2026. https://doi.org/10.2478/cttr-2026-0002.

Chicago

al, Ashraf-Khorassani Mehdi et. 2026. "Impact of HPLC Parameters on Chiral Separation of Nornicotine Enantiomers.". https://doi.org/10.2478/cttr-2026-0002.

Harvard

al, A. K. M. E. 2026, Impact of HPLC Parameters on Chiral Separation of Nornicotine Enantiomers, Sciendo, available at: https://doi.org/10.2478/cttr-2026-0002 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Impact of HPLC Parameters on Chiral Separation of Nornicotine Enantiomers
Autore / collaboratori
Ashraf-Khorassani Mehdi et al
Editore
Sciendo
Anno di pubblicazione
2026
ISSN
2719-9509
ISSN
2719-9509
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato