Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo de revista

Development and external validation of a musculoskeletal ultrasound-based prediction model for limited shoulder range of motion in nursing staff with neck–shoulder pain: a cross-sectional study

Rui Zhao et al · Frontiers Media S.A · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

3D intelligent printing technology-assisted training improves core competencies of clinical medicine interns: bridging undergraduate further education and community health service needs

Questa pubblicazione seriale contiene 107 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

BackgroundNurses with neck–shoulder pain are at high risk of developing limited shoulder range of motion (ROM), but early prediction tools are lacking. This study aimed to identify risk factors using clinical data and musculoskeletal ultrasound (MSKUS), and to develop and validate a prediction model.MethodsA total of 210 nurses with neck–shoulder pain (100 with limited ROM, 110 with normal ROM) from a tertiary hospital were enrolled. Univariate and multivariate logistic regression analyses were performed to establish a prediction model, which was externally validated in 63 additional nurses.ResultsMultivariate analysis identified age, average sleep duration on workdays (ASDW), daily overhead arm duration (DOAD), glenohumeral joint effusion (GLE), subacromial-subdeltoid bursa effusion (SASDBE), and long head of biceps tendon sheath effusion (LHBTE) as independent risk factors. The prediction model demonstrated excellent discrimination with an area under the ROC curve (AUC) of 0.956, sensitivity of 0.910, and specificity of 0.864. External validation yielded an AUC of 0.938, sensitivity of 0.833, and specificity of 0.821.ConclusionThe model incorporating age, ASDW, DOAD, GLE, SASDBE, and LHBTE shows excellent predictive performance for limited shoulder ROM in nursing staff with neck–shoulder pain.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, R. Z. E. (2026). Development and external validation of a musculoskeletal ultrasound-based prediction model for limited shoulder range of motion in nursing staff with neck–shoulder pain: a cross-sectional study. https://doi.org/10.3389/fpubh.2026.1830887

MLA

al, Rui Zhao et. "Development and external validation of a musculoskeletal ultrasound-based prediction model for limited shoulder range of motion in nursing staff with neck–shoulder pain: a cross-sectional study." 2026. https://doi.org/10.3389/fpubh.2026.1830887.

Chicago

al, Rui Zhao et. 2026. "Development and external validation of a musculoskeletal ultrasound-based prediction model for limited shoulder range of motion in nursing staff with neck–shoulder pain: a cross-sectional study.". https://doi.org/10.3389/fpubh.2026.1830887.

Harvard

al, R. Z. E. 2026, Development and external validation of a musculoskeletal ultrasound-based prediction model for limited shoulder range of motion in nursing staff with neck–shoulder pain: a cross-sectional study, Frontiers Media S.A, available at: https://doi.org/10.3389/fpubh.2026.1830887 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Development and external validation of a musculoskeletal ultrasound-based prediction model for limited shoulder range of motion in nursing staff with neck–shoulder pain: a cross-sectional study
Autore / collaboratori
Rui Zhao et al
Editore
Frontiers Media S.A
Anno di pubblicazione
2026
ISSN
2296-2565
ISSN
2296-2565
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato