Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo de revista

Application of foundation reinforcement by anchor-jacked piles under low clearance

WU Jiang-bin , WANG Xiang-jun , SONG Qing-jun · Editorial Office of Chinese Journal of Geotechnical Engineering · 2017

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

3D cross-hole resistivity inversion imaging of surrounding rock based on distance weighting constraint algorithm

Questa pubblicazione seriale contiene 241 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

For the a building with 13 floors high and no basemnt located in Shanghai, short leg shear wall system is used for the superstructure, and the foundation beams with precast tubular piles are used to be the foundation type. Before service of the project, may soils are pulled behind the building, and large deformation of the building is induced. For safety consideration, anchor-jacked piles are used to be as the foundation reinforcement. The steel pipe piles are used, which are the same as the existing ones. The total number is 116. In order to strengthen the rigidity of the original foundation and to make it easier for pile layout and load transfer, the raft with thickness of 700 mm is hoped to connect the existing foundation beams and the new piles. The steel pipe piles are located under the raft, and the raft will be the counterforce structure for the anchor-jacked pile. The connection node between piles and raft and that between raft and the existing foundation beams are proposed herein. The equipment is reformed to realize the construction of anchor-jacked piles under the clearance less than 2.5 m. So far, the maxium settlement of the building is about 10 mm, which shows the effect of the reinforcement by the anchor-jacked piles is remarkable.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

WU Jiang-bin, W. X. J. S. Q. J. (2017). Application of foundation reinforcement by anchor-jacked piles under low clearance. https://doi.org/10.11779/CJGE2017S2040

MLA

WU Jiang-bin, WANG Xiang-jun, SONG Qing-jun. "Application of foundation reinforcement by anchor-jacked piles under low clearance." 2017. https://doi.org/10.11779/CJGE2017S2040.

Chicago

WU Jiang-bin, WANG Xiang-jun, SONG Qing-jun. 2017. "Application of foundation reinforcement by anchor-jacked piles under low clearance.". https://doi.org/10.11779/CJGE2017S2040.

Harvard

WU Jiang-bin, W. X. J. S. Q. J. 2017, Application of foundation reinforcement by anchor-jacked piles under low clearance, Editorial Office of Chinese Journal of Geotechnical Engineering, available at: https://doi.org/10.11779/CJGE2017S2040 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Application of foundation reinforcement by anchor-jacked piles under low clearance
Autore / collaboratori
WU Jiang-bin , WANG Xiang-jun , SONG Qing-jun
Editore
Editorial Office of Chinese Journal of Geotechnical Engineering
Anno di pubblicazione
2017
ISSN
1000-4548
ISSN
1000-4548
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato