Dosimetric intercomparison for stereotactic radiotherapy of multiple brain metastases

Sara Abdollahi et al · Elsevier · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Background and purpose: Stereotactic radiotherapy (SRT) delivers high doses with submillimeter precision to small targets, requiring accuracy in both dose calculation and delivery. This study aimed to perform a dosimetric intercomparison of SRT accuracy across multiple radiotherapy departments. Materials and methods: The study included 30 SRT plans submitted by 24 hospitals. A head phantom, equipped with Gafchromic EBT3 film and ion chamber inserts, was used for dose measurements. Invited institutions generated SRT treatment plans prescribing 30 Gy in 5 fractions to brain targets, following their clinical protocols. Point dose and planar dose measurements were carried out at each institution, then the measured doses were compared against those calculated by their respective treatment planning systems. Agreement between planned and measured dose was assessed, with gamma passing rates calculated using 5%/1 mm and 3%/1 mm criteria. Results: An average difference of 0.2% and a range of − 4.1% to 4.3% between the ion chamber measured dose at the center of one of the targets and the calculated dose was found. For the 5%/1 mm global gamma criterion, all films achieved passing rates above 97%. All treatment devices showed sub-millimeter spatial dose delivery accuracy, with deviations under 1 mm between measured and planned dose. Conclusions: The results indicated clinically acceptable agreement between the calculated and delivered dose across all treatment delivery systems. This intercomparison provided an opportunity for radiotherapy departments to assess the quality of their SRT treatment planning and delivery and benchmark their performance against other institutions.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. A. E. (2026). Dosimetric intercomparison for stereotactic radiotherapy of multiple brain metastases. https://doi.org/10.1016/j.phro.2026.100956

MLA

al, Sara Abdollahi et. "Dosimetric intercomparison for stereotactic radiotherapy of multiple brain metastases." 2026. https://doi.org/10.1016/j.phro.2026.100956.

Chicago

al, Sara Abdollahi et. 2026. "Dosimetric intercomparison for stereotactic radiotherapy of multiple brain metastases.". https://doi.org/10.1016/j.phro.2026.100956.

Harvard

al, S. A. E. 2026, Dosimetric intercomparison for stereotactic radiotherapy of multiple brain metastases, Elsevier, available at: https://doi.org/10.1016/j.phro.2026.100956 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Dosimetric intercomparison for stereotactic radiotherapy of multiple brain metastases
Autore / collaboratori
Sara Abdollahi et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
2405-6316
ISSN
2405-6316
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato