Geometric accuracy of surface high-dose rate brachytherapy applicator and catheters identified using Dixon volumetric interpolated breath-hold examination magnetic resonance images

Evangelia Kaza et al · Elsevier · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Background and purpose: Volumetric Interpolated Breath-hold Examination (VIBE) magnetic resonance imaging (MRI) can depict flap applicators of High-Dose-Rate (HDR) surface brachytherapy. Evaluating criteria for catheter detection and assessing the geometric fidelity of detected applicators and catheters is important for VIBE implementation in HDR brachytherapy planning. Materials and methods: A fixed flat Freiburg Flap (FF) applicator (31 empty catheters, 21 spheres each) was imaged axially in a computed tomography (CT) scanner and 3 T MR simulator using Dixon VIBE. VIBE was repeated for three sagittal and coronal applicator placements. A novel algorithm detected applicator borders and catheters on central slices of in-phase (IP) and opposed-phase (OP) series, their geometric mean (GM), and reference CT scans. Obtained distances were compared against known dimensions. Applicator and catheter edge displacements between IP and OP images were measured. Results: All catheters were automatically identified on all series. Applicator lengths generally lay within 310 ± 1 mm. Catheter lengths were underestimated by up to 2 mm on original images due to reliance on surrogate tunneled beads. Adjacent catheter positions lay on average within 0.05 mm from their nominal 10.0 mm distance. Catheter angles were opposite between IP and OP images affected by chemical shift. GM corrected the relative applicator and catheter rotation. Average chemical shift induced IP-OP displacements were 2.3 ± 0.6 mm. Conclusions: Local signal intensity minima were reliable for empty catheter detection. Applicator shape and dimensions were preserved on individual IP and OP series. Chemical shift induced displacements amounted to 1.2 mm for individual images.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, E. K. E. (2026). Geometric accuracy of surface high-dose rate brachytherapy applicator and catheters identified using Dixon volumetric interpolated breath-hold examination magnetic resonance images. https://doi.org/10.1016/j.phro.2026.100955

MLA

al, Evangelia Kaza et. "Geometric accuracy of surface high-dose rate brachytherapy applicator and catheters identified using Dixon volumetric interpolated breath-hold examination magnetic resonance images." 2026. https://doi.org/10.1016/j.phro.2026.100955.

Chicago

al, Evangelia Kaza et. 2026. "Geometric accuracy of surface high-dose rate brachytherapy applicator and catheters identified using Dixon volumetric interpolated breath-hold examination magnetic resonance images.". https://doi.org/10.1016/j.phro.2026.100955.

Harvard

al, E. K. E. 2026, Geometric accuracy of surface high-dose rate brachytherapy applicator and catheters identified using Dixon volumetric interpolated breath-hold examination magnetic resonance images, Elsevier, available at: https://doi.org/10.1016/j.phro.2026.100955 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Geometric accuracy of surface high-dose rate brachytherapy applicator and catheters identified using Dixon volumetric interpolated breath-hold examination magnetic resonance images
Autore / collaboratori
Evangelia Kaza et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
2405-6316
ISSN
2405-6316
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato