Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Comparative evaluation of dose accumulation strategies in the clinical reirradiation setting

Natasa Solomou et al · Elsevier · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Background and purpose: Dose accumulation in reirradiation can contribute to both treatment outcomes and safe cumulative doses. We demonstrated consensus strategies on dose accumulation for three clinical reirradiation scenarios. Materials and methods: For a lung patient, prescription, point and volumetric-based dose accumulations were generated, while isodose transfer also highlighted a visual approach. In a head and neck case, three-dimensional conformal radiotherapy (3DRT) fields were reconstructed from treatment records. For a brachytherapy gynaecological case, isodose transfer and full volumetric dose accumulation were generated. For pertinent organs at risk (OARs) equieffective doses (EQD2Gy) enabled comparisons between the different methods. Results: Large variations in cumulative EQD2Gy values in the lung case were calculated. Assuming prescription EQD2Gy, values were 181.9, 161.4 and 154.6 Gy to the spinal canal, brachial plexus and pericardium. Median cumulative point EQD2Gy values for these organs were 15.9, 81.9, 66.6 Gy and similarly, volumetric dose values were 13.9, 68.9 and 55.2 Gy respectively. The head and neck re-simulation showed significant process limitations, especially for brainstem (11.8 – 34.4 Gy EQD2Gy). For the brachytherapy case, cumulative EQD2Gy values were similar across direct point and volumetric dose summation (88.5 vs 88.0 Gy for bladder; 83.6 vs 80.0 Gy for rectum). Conclusions: Different reirradiation dose accumulation strategies can lead to significant variations in reported OAR cumulative dose. Prescription and point-based dose methods tend to overestimate cumulative dose, which could justify their application in time critical situations, but may limit treatment options. More advanced volumetric-based methods demonstrated improved consistency in cumulative dose reporting.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, N. S. E. (2026). Comparative evaluation of dose accumulation strategies in the clinical reirradiation setting. https://doi.org/10.1016/j.phro.2026.100954

MLA

al, Natasa Solomou et. "Comparative evaluation of dose accumulation strategies in the clinical reirradiation setting." 2026. https://doi.org/10.1016/j.phro.2026.100954.

Chicago

al, Natasa Solomou et. 2026. "Comparative evaluation of dose accumulation strategies in the clinical reirradiation setting.". https://doi.org/10.1016/j.phro.2026.100954.

Harvard

al, N. S. E. 2026, Comparative evaluation of dose accumulation strategies in the clinical reirradiation setting, Elsevier, available at: https://doi.org/10.1016/j.phro.2026.100954 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Comparative evaluation of dose accumulation strategies in the clinical reirradiation setting
Autore / collaboratori
Natasa Solomou et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
2405-6316
ISSN
2405-6316
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato