← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial

Wonhyeong Lee et al · Elsevier · 2026

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

Background and purpose: A dummy run quality assurance was conducted for a prospective phase II trial of tailored radiotherapy (RT) according to the response after neoadjuvant chemotherapy (NAC) followed by surgery in locally advanced breast cancer (RTaNAC). Since inter-institutional variations in dose distributions can impact clinical outcomes, this dummy run aimed to develop an RT plan protocol to minimize these variations. Material and methods: This study involved computed tomography images from three clinical scenarios: RT with no lymph node (LN) boost (Scenario 1), LN boost up to 60 Gy3.5, equivalent dose in 2 Gy fractions (EQD2) with α/β = 3.5 Gy (Scenario 2), and LN boost up to 66 Gy3.5 (Scenario 3). Seven institutions developed RT plans under a two-step process: first according to each institution’s policies (Step 1) and then using additional reference information, including artificial intelligence (AI) auto-contoured structures and LN boost target volume information (Step 2). Dose-volume histograms for breast and regional nodal areas were analyzed between the two steps. Results: Inter-institutional variation observed in Step 1 improved in Step 2 for breast and regional nodal areas. Specifically for Scenario 1, dose coverage for the nodal clinical target volumes of the axillary level I LN improved from 57.5% to 97.5% (p-value = 0.075), and that of the supraclavicular LN improved from 75.6% to 88.8% (p-value = 0.046). Conclusion: Variations in dose/volume metrics among institutions were mitigated by AI auto-contoured structures and LN boost target volume information. Through this dummy run, the participating institutions reached a consensus on an RT plan protocol to support multi-institutional expansion of RTaNAC.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, W. L. E. (2026). Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial. https://doi.org/10.1016/j.phro.2026.100949

MLA

al, Wonhyeong Lee et. "Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial." 2026. https://doi.org/10.1016/j.phro.2026.100949.

Chicago

al, Wonhyeong Lee et. 2026. "Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial.". https://doi.org/10.1016/j.phro.2026.100949.

Harvard

al, W. L. E. 2026, Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial, Elsevier, available at: https://doi.org/10.1016/j.phro.2026.100949 [Accessed 30 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial
Autor / colaboradores
Wonhyeong Lee et al
Editorial
Elsevier
Año de publicación
2026
ISSN
2405-6316
ISSN
2405-6316
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado