Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations

Yaotao Li et al · Elsevier · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Background and Purpose: Craniospinal irradiation (CSI) is a critical treatment modality for central nervous system (CNS) tumors. This study aimed to compare the dose-volume parameters and treatment efficiency between O-ring and C-arm linear accelerators (linacs) for CSI. Materials and Methods: A systematic search of English and Chinese databases was conducted from January 2005 to January 2026. Studies were evaluated using the PICOS framework. Data extraction and meta-analysis were performed using Stata 18.0 software encompassing subgroup analysis. Results: Twelve studies involving 87 patients were included. No significant differences were found in dose to the planning target volume (PTV) between O-ring and C-arm linacs (Dmax: standardized mean difference (SMD) = -0.14, 95% confidence interval (CI): −0.61 to 0.32; Dmean: SMD = −0.53, 95% CI: −1.57 to 0.50). However, O-ring linacs, including dual-layer multi-leaf collimator linacs (DLM-linac) and helical radiotherapy (HR), delivered significantly lower maximum doses (Dmax) to the heart and liver (heart Dmax: SMD = -1.53, 95% CI: −2.53 to −0.52, p = 0.003; liver Dmax: SMD = -1.33, 95% CI: −2.29 to −0.37, p = 0.007). Subgroup analysis revealed that DLM-linac significantly reduced Dmax to the eyes and esophagus compared to C-arm linacs (eyes Dmax: SMD = -0.62, 95% CI: −1.22 to −0.01, p = 0.045; esophagus, Dmax: SMD = -0.45, 95% CI: −0.89 to −0.01, p = 0.044). Additionally, HR had the highest monitor units and the longest treatment time among all linac types. Conclusions: Both O-ring and C-arm linacs are effective for CSI. No significant difference in PTV dose was revealed when the doses to the lungs and thyroid are comparable. However, O-ring linacs, particularly DLM-linac, provide superior protection for critical organs such as eyes and esophagus without extending treatment time. Considering both dose advantage and treatment efficiency, DLM-linac is a suitable radiotherapy treatment modality for CSI.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Y. L. E. (2026). A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations. https://doi.org/10.1016/j.phro.2026.100943

MLA

al, Yaotao Li et. "A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations." 2026. https://doi.org/10.1016/j.phro.2026.100943.

Chicago

al, Yaotao Li et. 2026. "A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations.". https://doi.org/10.1016/j.phro.2026.100943.

Harvard

al, Y. L. E. 2026, A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations, Elsevier, available at: https://doi.org/10.1016/j.phro.2026.100943 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations
Autore / collaboratori
Yaotao Li et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
2405-6316
ISSN
2405-6316
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato