Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Electrochemical glucose sensing using an electrochemically reduced graphene oxide/poly-L-lysine composite electrode modified with glucose oxidase

Xiaofei Zhang et al · Elsevier · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Facilitating efficient electrical communication between glucose oxidase (GOx) and electrode surfaces is important for the development of low-potential reagent-free glucose biosensors, yet unequivocal direct electron transfer (DET) for native GOx remains controversial because the FAD redox center is deeply buried within the protein structure. In this work, a one-step electrochemical co-deposition strategy was used to fabricate an electrochemically reduced graphene oxide/L-lysine (ERGO–Lys) nanocomposite on glassy carbon. The resulting interface exhibited a pair of well-defined redox peaks centered at −0.460 V (vs Ag/AgCl) and glucose-responsive behavior under rigorously deoxygenated conditions. Given the continuing debate surrounding native GOx DET at carbon nanomaterials, these results are interpreted conservatively as DET-like (pseudo-DET) bioelectrochemistry rather than definitive proof of true DET. Under anaerobic conditions, the biosensor showed a linear range of 5 μM to 9.0 mM, a sensitivity of 35.8 μA·mM⁻¹ ·cm⁻², and a limit of detection of 1.8 μM. The sensor also retained 90% of its initial response after two weeks and showed low interference at −0.40 V.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, X. Z. E. (2026). Electrochemical glucose sensing using an electrochemically reduced graphene oxide/poly-L-lysine composite electrode modified with glucose oxidase. https://doi.org/10.1016/j.ijoes.2026.101357

MLA

al, Xiaofei Zhang et. "Electrochemical glucose sensing using an electrochemically reduced graphene oxide/poly-L-lysine composite electrode modified with glucose oxidase." 2026. https://doi.org/10.1016/j.ijoes.2026.101357.

Chicago

al, Xiaofei Zhang et. 2026. "Electrochemical glucose sensing using an electrochemically reduced graphene oxide/poly-L-lysine composite electrode modified with glucose oxidase.". https://doi.org/10.1016/j.ijoes.2026.101357.

Harvard

al, X. Z. E. 2026, Electrochemical glucose sensing using an electrochemically reduced graphene oxide/poly-L-lysine composite electrode modified with glucose oxidase, Elsevier, available at: https://doi.org/10.1016/j.ijoes.2026.101357 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Electrochemical glucose sensing using an electrochemically reduced graphene oxide/poly-L-lysine composite electrode modified with glucose oxidase
Autore / collaboratori
Xiaofei Zhang et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
1452-3981
ISSN
1452-3981
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato