Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Dynamic Changes in Exhaled Breath Glucose by Condensate Collection During Oral Glucose Tolerance Testing in Healthy Adults

Xu W et al · Dove Medical Press · 2026

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo
Otras opciones de acceso Elegí el proveedor disponible para esta ficha.
Importación CSV DOAJ - Open Access Journals
Acceder por Importación CSV
DOAJ OAI-PMH DOAJ Articles
Acceder por DOAJ OAI-PMH
DOAJ CSV Export DOAJ - Open Access Journals
Acceder por DOAJ CSV Export

Altre opzioni disponibili

Se la risorsa è presente su più piattaforme, puoi scegliere dove aprirla.

Importación CSV DOAJ - Open Access Journals Accesso disponibile
Apri
DOAJ OAI-PMH DOAJ Articles Accesso disponibile
Apri
DOAJ CSV Export DOAJ - Open Access Journals Accesso disponibile
Apri

Riepilogo

Descripción general del contenido del recurso.

Wen Xu,1 Qingping Zhang,1 Yilian Hong,1 Zhenjun Mao2 1Department of Internal Medicine, University Campus, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang, People’s Republic of China; 2Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang, People’s Republic of ChinaCorrespondence: Wen Xu, Department of Internal Medicine, University Campus, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang, 310012, People’s Republic of China, Email zjxuwen1982@zju.edu.cnPurpose: Invasive blood glucose monitoring is associated with pain and suboptimal patient adherence, creating a need for non-invasive alternatives. In this study, we investigated the dynamic relationship between glucose levels in exhaled breath and blood during an oral glucose tolerance test (OGTT) in healthy adults, to assess the feasibility of using exhaled breath glucose as a non-invasive marker for glycemic monitoring.Methods: Twenty healthy volunteers (12 males, 8 females; mean age 23.1 ± 2.4 years) underwent a standardized OGTT test. Exhaled breath condensate (EBC) and blood samples were collected simultaneously at fasting (0h) and at 0.5h, 1h, 2h, and 3h post-glucose load. EBC glucose concentration was measured using ion chromatography. The temporal profiles of both parameters were analyzed, and the correlation between the rate of change in exhaled breath glucose and blood glucose at each time point was assessed using Pearson or Spearman correlation test.Results: Both blood glucose and exhaled breath glucose exhibited similar temporal patterns, peaking within 0.5– 1 h after glucose administration and returning to baseline by 3h. Exhaled breath glucose increased from a fasting level of 0.49 ± 0.11 ng/L to a peak of 4.07 ± 1.44 ng/L at 1h. A statistically significant positive correlation between the rate of change in exhaled breath glucose and blood glucose was observed at 1h (r = 0.84, p < 0.000), whereas the correlation at 0.5h was not significant after correction for multiple comparisons (ρ = 0.45, adjusted p = 0.196). No significant correlations were detected at 2h or 3h. The changes in exhaled breath glucose were not associated with baseline pulmonary function—as measured by forced vital capacity (p > 0.05).Conclusion: Exhaled breath glucose levels dynamically track blood glucose changes during the early postprandial phase in healthy adults, demonstrating strong concordance during periods of rapid glycemic excursion. These findings support the feasibility of EBC as a non-invasive tool for monitoring glycemic trends. Further validation in larger cohorts and diabetic patients is required to establish its clinical utility.Keywords: exhaled breath condensate, EBC, oral glucose tolerance testing, OGTT, invasive blood monitor

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, X. W. E. (2026). Dynamic Changes in Exhaled Breath Glucose by Condensate Collection During Oral Glucose Tolerance Testing in Healthy Adults. https://nodovox.com/record.php?id=323715

MLA

al, Xu W et. "Dynamic Changes in Exhaled Breath Glucose by Condensate Collection During Oral Glucose Tolerance Testing in Healthy Adults." 2026. https://nodovox.com/record.php?id=323715.

Chicago

al, Xu W et. 2026. "Dynamic Changes in Exhaled Breath Glucose by Condensate Collection During Oral Glucose Tolerance Testing in Healthy Adults.". https://nodovox.com/record.php?id=323715.

Harvard

al, X. W. E. 2026, Dynamic Changes in Exhaled Breath Glucose by Condensate Collection During Oral Glucose Tolerance Testing in Healthy Adults, Dove Medical Press, available at: https://nodovox.com/record.php?id=323715 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Dynamic Changes in Exhaled Breath Glucose by Condensate Collection During Oral Glucose Tolerance Testing in Healthy Adults
Autore / collaboratori
Xu W et al
Editore
Dove Medical Press
Anno di pubblicazione
2026
ISSN
1179-1470
ISSN
1179-1470
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato