Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification

Chris Barnes et al · SpringerOpen · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Background We previously reported the first-in-human evaluation of 3-[18F]-fluoro-2,2-dimethylpropionic acid ([18F]FPIA) for imaging aberrant lipid metabolism and cancer detection. The first-generation semi-automated radiosynthesis of [18F]FPIA required HPLC purification to provide injection solution devoid of precursor (methyl 2,2-dimethyl-3-[(4-methylbenzenesulfonyl)oxy]propanoate), radioactive intermediate (methyl-3-([18F]fluoro)-2,2-dimethylpropanoate), and potential chemical impurities (tosic acid, 3-hydroxy-2,2-dimethylpropanoic acid and unlabelled FPIA). In readiness for global use of [18F]FPIA, we report a significant improvement to the GMP production through development of a fully-automated solid-phase extraction (SPE) purification method. Results We developed a fully-automated SPE purified radiosynthesis on FASTLab™ for GMP readiness that was translated to and validated on the Trasis AIO™ platform for routine clinical use. Purification of the radiotracer by SPE on both systems was achieved (> 98% radiochemical purity), increasing the radiochemical yield compared to the HPLC-based purification method. Non-decay-corrected radiochemical yields (RCY, n.d.c) were 30.3 ± 2.3% (n = 8) and 25.8 ± 6.6% (n = 46) on GE FASTlab™ and Trasis AIO™, respectively. Non-radioactive FPIA and other analytes determined by HPLC were below the limit of detection (< 1.0 µg/mL) from GE FASTlab™ and ≤ 1.2 µg/mL from Trasis AIO™. Conclusions The synthesis of [18F]FPIA was validated on the Trasis AIO™ platform for GMP production and is currently used to produce clinical doses for phase II clinical trials. Readiness for GMP validation was also demonstrated on GE FASTlab™ and can be adopted on other automated platforms.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. B. E. (2026). An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification. https://doi.org/10.1186/s41181-026-00440-4

MLA

al, Chris Barnes et. "An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification." 2026. https://doi.org/10.1186/s41181-026-00440-4.

Chicago

al, Chris Barnes et. 2026. "An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification.". https://doi.org/10.1186/s41181-026-00440-4.

Harvard

al, C. B. E. 2026, An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification, SpringerOpen, available at: https://doi.org/10.1186/s41181-026-00440-4 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification
Autore / collaboratori
Chris Barnes et al
Editore
SpringerOpen
Anno di pubblicazione
2026
ISSN
2365-421X
ISSN
2365-421X
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato