← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach

Chiara Robba et al · BMC · 2026

Acceso abierto disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Acceso abierto disponible

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Abrir recurso

Resumen

Descripción general del contenido del recurso.

Abstract Invasive intracranial pressure (ICP) monitoring is considered the gold standard for the management of patients with an acute brain injury and at risk of developing intracranial hypertension (IH). However, invasive devices (e.g., intraparenchymal probe or external ventricular drain) are expensive, not available worldwide, and might be associated with some risks. Recently, a consensus for the monitoring and management of traumatic brain injury (TBI) patients when invasive ICP is not available (B-ICONIC) was developed. This approach is based on repeated neurological evaluation, neuroimaging, and the use of non-invasive ICP monitoring tools, such as transcranial Doppler, automated pupillometry, and ultrasound optic nerve sheath diameter measurement, to titrate interventions aiming at controlling ICP. Despite this clinical algorithm was mainly proposed for low and middle-income countries where invasive ICP is not widely implemented, a potential application of this approach may exist even in healthcare facilities where direct ICP monitoring is available. This includes patients who may have contraindications to invasive monitoring, such as coagulopathy, as well as those in whom ICP monitoring is not routinely implemented, such as individuals with post-anoxic brain injury or acute liver failure, for the reported occurrence of cerebral edema and potential risk of IH in these cases. Therefore, the aim of this manuscript is to propose the extension of the B-ICONIC algorithm to a wider population, regardless of the decision to insert an ICP sensor, and to guide their management using this multimodal approach.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. R. E. (2026). Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach. https://doi.org/10.1186/s44158-026-00356-0

MLA

al, Chiara Robba et. "Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach." 2026. https://doi.org/10.1186/s44158-026-00356-0.

Chicago

al, Chiara Robba et. 2026. "Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach.". https://doi.org/10.1186/s44158-026-00356-0.

Harvard

al, C. R. E. 2026, Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach, BMC, available at: https://doi.org/10.1186/s44158-026-00356-0 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach
Autor / colaboradores
Chiara Robba et al
Editorial
BMC
Año de publicación
2026
ISSN
2731-3786
ISSN
2731-3786
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado