Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach

Chiara Robba et al · BMC · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Invasive intracranial pressure (ICP) monitoring is considered the gold standard for the management of patients with an acute brain injury and at risk of developing intracranial hypertension (IH). However, invasive devices (e.g., intraparenchymal probe or external ventricular drain) are expensive, not available worldwide, and might be associated with some risks. Recently, a consensus for the monitoring and management of traumatic brain injury (TBI) patients when invasive ICP is not available (B-ICONIC) was developed. This approach is based on repeated neurological evaluation, neuroimaging, and the use of non-invasive ICP monitoring tools, such as transcranial Doppler, automated pupillometry, and ultrasound optic nerve sheath diameter measurement, to titrate interventions aiming at controlling ICP. Despite this clinical algorithm was mainly proposed for low and middle-income countries where invasive ICP is not widely implemented, a potential application of this approach may exist even in healthcare facilities where direct ICP monitoring is available. This includes patients who may have contraindications to invasive monitoring, such as coagulopathy, as well as those in whom ICP monitoring is not routinely implemented, such as individuals with post-anoxic brain injury or acute liver failure, for the reported occurrence of cerebral edema and potential risk of IH in these cases. Therefore, the aim of this manuscript is to propose the extension of the B-ICONIC algorithm to a wider population, regardless of the decision to insert an ICP sensor, and to guide their management using this multimodal approach.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. R. E. (2026). Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach. https://doi.org/10.1186/s44158-026-00356-0

MLA

al, Chiara Robba et. "Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach." 2026. https://doi.org/10.1186/s44158-026-00356-0.

Chicago

al, Chiara Robba et. 2026. "Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach.". https://doi.org/10.1186/s44158-026-00356-0.

Harvard

al, C. R. E. 2026, Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach, BMC, available at: https://doi.org/10.1186/s44158-026-00356-0 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Non-invasive ICP monitoring when invasive systems are available in the care of acute brain injured patients: a clinical approach
Autore / collaboratori
Chiara Robba et al
Editore
BMC
Anno di pubblicazione
2026
ISSN
2731-3786
ISSN
2731-3786
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato