Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Effect of optical impression, timing of dentin sealing application and cavity design optimization on microleakage of ceramic onlays: an in vitro study

Hanan Ahmed Nabil Soliman et al · BMC · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Statement of problem Immediate dentin sealing (IDS) is used to improve bonding of indirect restoration. However, interaction between polyether impressions may affect the future bonding of indirect restoration. So, digital impressions with IDS may have a better impact on microleakage. Purpose The current in vitro study aimed to investigate the effect of using digital impression versus polyether impression and different dentin sealing techniques on the microleakage of lithium disilicate onlays. Material and methods A total of 60 identically sized human mandibular molars were allocated into two groups (n = 30): group DI, which uses a digital impression, and group CI, which uses a polyether impression. After preparation of all teeth for onlay, based on the dentin sealing technique, these groups were further divided into three subgroups (n = 10): subgroups I, II, and III. Dentin sealing was postponed in subgroup I prior to cementation. Immediate dentin sealing was applied prior to impression processes in subgroups II and III, plus cavity design optimization (CDO) for subgroup III. All teeth received e.max CAD onlay restoration (Ivoclar Vivadent, Schaan, Liechtenstein). The specimens were exposed to thermocycling with bath temperatures of 5 °C and 55 °C for a total of 5000 cycles. The specimens were then submerged in 0.5% aqueous Rhodamine B dye for 48 h. Buccolingual sections were examined under confocal microscopy. Microleakage was scored (0–3). Data were analyzed using the Scheirer–Ray–Hare test (α = 0.05). Results Microleakage was significantly lower in DI than CI (P=.0046). Delayed dentin sealing (subgroup I) showed significantly higher microleakage than IDS (subgroup II) and IDS + CDO (subgroup III) (P<.001), with no significant difference between IDS and IDS + CDO. Conclusions Digital impressions were associated with significantly lower microleakage compared to polyether impressions. IDS, with or without CDO, significantly reduced microleakage compared to delayed sealing. Clinical implications Combining digital impressions with IDS may enhance the marginal seal and longevity of ceramic onlays.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. A. N. S. E. (2026). Effect of optical impression, timing of dentin sealing application and cavity design optimization on microleakage of ceramic onlays: an in vitro study. https://doi.org/10.1186/s12903-026-08348-w

MLA

al, Hanan Ahmed Nabil Soliman et. "Effect of optical impression, timing of dentin sealing application and cavity design optimization on microleakage of ceramic onlays: an in vitro study." 2026. https://doi.org/10.1186/s12903-026-08348-w.

Chicago

al, Hanan Ahmed Nabil Soliman et. 2026. "Effect of optical impression, timing of dentin sealing application and cavity design optimization on microleakage of ceramic onlays: an in vitro study.". https://doi.org/10.1186/s12903-026-08348-w.

Harvard

al, H. A. N. S. E. 2026, Effect of optical impression, timing of dentin sealing application and cavity design optimization on microleakage of ceramic onlays: an in vitro study, BMC, available at: https://doi.org/10.1186/s12903-026-08348-w [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Effect of optical impression, timing of dentin sealing application and cavity design optimization on microleakage of ceramic onlays: an in vitro study
Autore / collaboratori
Hanan Ahmed Nabil Soliman et al
Editore
BMC
Anno di pubblicazione
2026
ISSN
1472-6831
ISSN
1472-6831
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato