Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis

Abdulaziz Gul et al · BMC · 2026

Acceso abierto disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Acceso abierto disponible

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Abrir recurso

Resumen

Descripción general del contenido del recurso.

Abstract Background Various designs of dental implants made of zirconium dioxide (zirconia) as an alternative to titanium implants are available as one-piece implant (OPI) or as bone-level or tissue-level two-piece implants (TPI) with either ceramic or titanium abutment screw types of implant-abutment connections. This study aimed to identify and quantify stress concentrations and levels across different zirconia implant designs under a quasi-static external load. Methods The study used a finite element analysis (FEA) simulation model, including five zirconia implant design models of OPI and bone-level and tissue-level TPI zirconia implants with either ceramic or titanium abutment screw, to calculate and locate maximum principal (σ1) and minimum principal (σ3) and equivalent (von Mises) stresses under 400N of quasi-static loading at a 30-degree angle within ISO14801:2016 geometry and boundary conditions. The FEA assumed linear elastic and isotropic material properties. Results OPI showed high stress concentrations at the implant body’s external thread above the specimen holder. TPIs showed similar maximum principal stress (σ1) areas in their implant body, while minimum principal stress (σ3) occurred in the implant–abutment interface at the abutment neck, and the corresponding area in the implant platform. The TPIs with ceramic screws exhibited the highest stresses at the screw–abutment interface. Conclusions Within the limitations of this study, under a static oblique load applied within the ISO 14801:2016 geometry condition, stress distributions differ between OPI and TPI. TPIs show lower stress within the implant body but higher stress transfer to the specimen holder compared with OPI. Tissue-level TPIs exhibit lower stress than bone-level designs, whereas stresses in the abutment and screw depend on screw design and material. TPIs with ceramic screws exhibit higher stress levels compared to titanium screw.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. G. E. (2026). Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis. https://doi.org/10.1186/s12903-026-08192-y

MLA

al, Abdulaziz Gul et. "Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis." 2026. https://doi.org/10.1186/s12903-026-08192-y.

Chicago

al, Abdulaziz Gul et. 2026. "Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis.". https://doi.org/10.1186/s12903-026-08192-y.

Harvard

al, A. G. E. 2026, Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis, BMC, available at: https://doi.org/10.1186/s12903-026-08192-y [Accessed 28 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis
Autor / colaboradores
Abdulaziz Gul et al
Editorial
BMC
Año de publicación
2026
ISSN
1472-6831
ISSN
1472-6831
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado