Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Bridging the gap in PCNL preoperative planning: software-free stone metrics that outperform conventional measures

Bingjian Wei et al · BMC · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Objective Accurate preoperative stone size assessment is crucial for predicting outcomes after percutaneous nephrolithotomy (PCNL), yet a gap persists between the accurate but impractical gold standard (3D software volume) and the practical but suboptimal conventional metrics (maximum diameter and cross-sectional area). This study aimed to validate two novel, software-free stone size metrics—the triaxial diametric product (X) and stacked volume (V)—designed for routine clinical computed tomography (CT) and compare their efficacy in predicting the stone-free rate (SFR) against conventional methods. Methods We conducted a retrospective analysis of 283 patients who underwent PCNL. Stone size was measured using four metrics on pre-operative non-contrast CT: maximum diameter (R), maximum cross-sectional area (S), triaxial diametric product (X = x·y·z), and stacked volume (V). The predictive power for SFR was evaluated and compared using receiver operating characteristic (ROC) curve analysis and DeLong’s test. Results All four metrics were significant predictors of SFR (p < 0.001). The predictive accuracy, ranked by the area under the curve (AUC), was as follows: maximum diameter (R, AUC = 0.703) < maximum cross-sectional area (S, AUC = 0.734) < triaxial diametric product (X, AUC = 0.789) < stacked volume (V, AUC = 0.801). The novel metrics X and V both significantly outperformed the conventional metrics R and S (p < 0.01), with no significant difference between X and V. Conclusion The triaxial diametric product (X) is recommended as a practical and more accurate alternative to conventional metrics for routine clinical practice, especially for stones > 1.5 cm, as it offers an improved balance of predictive accuracy, straightforward calculation, and easy integration into existing workflows without needing specialized software or additional costs. The stacked volume (V) serves as a feasible, software-free tool for practical size estimation in research settings. This study provides urologists with immediately applicable tools to enhance preoperative planning.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, B. W. E. (2026). Bridging the gap in PCNL preoperative planning: software-free stone metrics that outperform conventional measures. https://doi.org/10.1186/s12894-026-02110-8

MLA

al, Bingjian Wei et. "Bridging the gap in PCNL preoperative planning: software-free stone metrics that outperform conventional measures." 2026. https://doi.org/10.1186/s12894-026-02110-8.

Chicago

al, Bingjian Wei et. 2026. "Bridging the gap in PCNL preoperative planning: software-free stone metrics that outperform conventional measures.". https://doi.org/10.1186/s12894-026-02110-8.

Harvard

al, B. W. E. 2026, Bridging the gap in PCNL preoperative planning: software-free stone metrics that outperform conventional measures, BMC, available at: https://doi.org/10.1186/s12894-026-02110-8 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Bridging the gap in PCNL preoperative planning: software-free stone metrics that outperform conventional measures
Autore / collaboratori
Bingjian Wei et al
Editore
BMC
Anno di pubblicazione
2026
ISSN
1471-2490
ISSN
1471-2490
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato